Programming field 1
All operating parameters can be selected and changed here. The
operating parameters blocked for the operator are also displayed.
Line 1
PC - Main counter (current counter status)
Line 2
P1 - Preset value 1
Line 3
P2 - Preset value 2
Line 4
SC - Start count
Line 5
∑ - Totalizer
Line 6
- Hour counter
Line 7
SF - Scaling factor
The dash line indicates the end of the first programming field.
Advance to Programming field 2 with the
key.
Programming field 2
The individual operation parameters for operator access are
disabled or enabled here.
„Stat“
appears in the display.
●
The current status value appears in the display. The respective
LED for the selected line XP, P1, P2, SC, ∑ or flashes.
(There is no LED for the SF scaling factor).
Meaning of status numbers
0
It is possible to select, read and modify the operation para-
meter on the operator level. (free access)
1
It is possible to select and read the operation parameter on
the operator level. (display only)
2
It is impossible to select the operation parameter on the
operator level. Its corresponding function is however su-
stained. (disabled)
Change status
Input the appropriate status number via the keys
and
.
The changed status will automatically be stored when the next
programming line is selected with key
.