Operating mode:
Line 22 to 2 = Parallel
comparison
Reset mode: Line 29 to 2
with automatic reset
RESET
VW (P2)
VW (P1)
O
OUT P1
OUT P2
Operating mode:
Line 22 to 3 = Schlepp-
vorwahl
VW (P1) corresponds
to the interval between
P1 and P2. When P2 is
changed, P1 is trailed.
RESET
VW (P2)
O (SC)
OUT P1
OUT P2
VW (P1)
Operating mode:
Line 22 to 0 = Trailing
preset Reset mode: Line
29 to 4 without automatic
reset, external RESET
with Start function.
OUT P1 and OUT P2 are
activated via the external
RESET and deactivated
when the preselection is
reached.
VW (P2)
O (SC)
OUT P1
OUT P2
RESET
VW (P1)
SC
VW (P2)
OUT P1
OUT P2
RESET
VW (P1)
9 Technical data
Technical data - electrical range
Voltage supply
14...28 VAC (50/60 Hz)
85...265 VAC (50/60 Hz)
10...30 VDC
Power consumption
5 VA, 4 W
Sensor supply
18 VDC ±15 % / 100 mA
Display
LED, 7-segment display
Number of digits
6-digits
Digit height
7.6 mm
Function
Preset-/Main counter with 2 presets
Totalizer, Hour counter
Scaling factor
0.0001...9999.99
Count modes
Adding or subtracting
A-B (difference counting)
A+B total (parallel counting)
Up/Down
A 90° B phase evaluation
Counting frequency
3 Hz, 25 Hz, 10 kHz programmable
Operating modes
Step preset, Main preset,
Parallel alignment, Trailing preset