NE212
50
www.baumer.com
Programming field 1
Information on the displays and changing individual values is also
given in part 4.
➜
Press the
key again.
●
The operating parameters are now called up. The respective LED
flashes.
To change operating param.
➜
Input the new value via the numerical keypad.
Line 1
SC
XP - Current counter status
Line 2
SC
P1 - Preset value 1
Line 3
SC
P2 - Preset value 2
Line 4
SC
SC - Main counter start count value
Line 5
SC
∑ - Totalizer
Line 6
SC
XB - Batch counter status
Line 7
SC
B1 - Batch counter preset value
Line 8
SC
- Time meter
After the conclusion of the first programming segment, a broken
line appears in the display.
Programming procedure for removing the sign from ∑:
-Select line 5 (∑).
-Erase totalizing counter with the
key.
-Operate the
+/-
key; „-oFF 0“ appears in the display.
-The function can be activated or cut out with the repeated applica-
tion of the
+/-
key.
-When the line with the „-oFF 0“ display is left, the output of the
sign by the totalizing counter is suppressed.