The user is responsible for ensuring that a switching load of 8A /
150 VA (W) is not exceeded in the event of a fault. Internal spark
suppression by means of two zinc oxide varistors (275 V). The output
relays of the instrument (1 relay or several) may only be disengaged
in
total 5 x per minute at the most. Admissible clicks
according
to interference suppression standard EN 61000-6-4 for the industrial
sector. In case of a higher switching rate, the operator must take
care of interference suppression on the spot and under his own
responsibility by observing the load to be switched.
➜
Assign terminals 4, 5, 6, 7, 8, 9 and 10, 11 (relay contact outputs)
accordingly.
3.3 Assignment electronic output
NPN
E
K
B
PNP
K
E
B
The electronic outputs (terminals 5, 8 and 11) are programmed by
the factory as NPN or PNP switching transistors (open collectors)
in accordance with purchase order specification. The outputs are
programmed as pulse or continuous signals in the programming
mode (lines 31, 32 and 33).
Output logic
Max. voltage
Max. current
NPN
+35 V
50 mA
PNP
+24 VDC
50 mA
The electronic output is not short-circuit proof.
➜
Assign terminals 5, 8 and 11 accordingly.
3.4 Assignment signal input
Terminals 12 to 17 are AC optocoupler inputs that may be triggered
by any PNP or NPN encoder. The required input logic can be assi-
gned at the connecting terminal by wire jumper (refer also to assi-
gning the input logic).
Specification of the inputs:
Terminal 12
Main counter counting input track A
Terminal 13
Main counter counting input track B
Terminal 16
Batch counter counting input
Max. frequency
15 Hz / 25 Hz / 10 kHz
(Programming line 24, 25, 26)
Input resistor
1.65 kΩ
Pegel low
0...0.8 V
Pegel high
14…27 V
Terminal 14
Main counter reset
Terminal 17
Batch counter reset