Type

Mode

Counting inputs

INP A

INP B

ISI36.010AX01

ISI36.011AX01

Tachometer

0

0 ... 0,7 V DC

NPN

7 kHz

0 ... 0,7 V DC

NPN         30 Hz

0

4 ... 30 V DC

PNP

12 kHz

4 ... 30 V DC

PNP

Options: 

x = A: no backlight
x = B: with backlight 

Table 1

Overview

Main technical features:

Display:

LCD, 8 decades, height of the figures 8 mm

Display range:

0 ... 99999999 with leading 
zeros suppression

Display unit:

1 s

Max. frequency (Pulse/pause: 1:1):

12 kHz

Min. frequency:

1 Hz

Display refresh:

1 s

Measuring principle: The tachometer operates via the gate 

measuring method. The incoming pulses are
counted during a measuring time of 1 s
and recalculated in order to display 1/s.

Accuracy:

< 0,05 %

Housing:

Panel mounting, 48 x 24 mm 
according to DIN 43 700, RAL 7021

Panel cut-out:

22,2

+0,3 

x 45

+0,6

mm

Mounting depth: 

approximately 48 mm

Weight:

approximately 50 g

Protection level:

IP65 on the front side

Connection:

Screw terminals, RM 5.00, 8 poles
Rated cross-section: max.: 1 x 1,5 mm

2

2 x 0,75 mm

2

AWG 26-14

EMC:

Interference emissions EN55011 Class B
Interference resistance EN 61000-6-2

Power supply:

Non-replaceable lithium battery 
(lifetime approximately 8 years at 20°C)

Working temperature:

–10 ... +55 °C, relative humidity < 85%, 
without condensation 

Operating temperature:

–10 ... +60 °C

Storage temperature:

–20 ... +70 °C

Altitude:

to 2000 m

Backlighting:

must be powered by an external 
elecrical source 
(24 V ±20%, 50 mA)

e

n

g

lis

h

ISI36

www.baumer.com

7

1.10 Failure possibilities and causes

Counter does not count:
- Wrong or reversed wiring of the counting input
- Polarity (NPN/PNP) reversed
- No ground connection between the pulse generator and the

counter

- Signal levels do not reach the switching threshold of the counter

If, despite all, your device still does not operate, contact your
local representative or call us directly for technical support.

When sending your device back, please attach a short descrip-
tion of the failure, of the programming and of the connection
diagram, in order to allow us to reproduce a possibly existing
defect and to repair your device as quickly as possible.

Содержание ISI36

Страница 1: ...ions d utilisation Indicateur de tr quence tachym tre ISI36 Baumer IVO GmbH Co KG 04 10 171 55 258 4 Dauchinger Strasse 58 62 DE 78056 Villingen Schwenningen Phone 49 0 7720 942 0 Fax 49 0 7720 942 90...

Страница 2: ...rekten Kontakt mit tzenden Fl ssigkeiten hei em Dampf oder hnlichen Achten Sie bei der Installation auf eine ausreichende K hlung des Ger tes 1 5 Montageanleitung Befestigungsrahmen vom Ger t abziehen...

Страница 3: ...Hz 04 30 V DC PNP 12 kHz 04 30 V DC PNP Optionen x A ohne Hintergrundbeleuchtung x B mit Hintergrundbeleuchtung Tabelle 1 Allgemeine technische Daten Anzeige LCD 8 stellig Ziffernh he 8 mm Anzeigebere...

Страница 4: ...B BL Nr 8 BL Hintergrund beleuchtung 0 V DC GND Tabelle 2 Lieferumfang Digitalanzeige Spannb gel Frontrahmen f r Schraubbefestigung Einbauquerschnitt 50 x 25 mm Frontrahmen f r Spannb gelbefestigung E...

Страница 5: ...V DC BL BL INP A INP B n c n c GND 24 V DC 20 50 mA 1 2 3 4 5 6 7 8 n c BL BL INP A INP B n c n c GND 1 2 3 4 5 6 7 8 n c max 30 V DC 24 V DC 20 50 mA DC Typ ISI36 011AX01 DC Typ ISI36 010AX01 ISI36 d...

Страница 6: ...corrosive liquids hot steam or similar When mounting the device make sure it is sufficiently cooled 1 5 Mounting instructions Remove the mounting clip from the device Insert the device from the front...

Страница 7: ...ction max 1 x 1 5 mm2 2 x 0 75 mm2 AWG 26 14 EMC Interference emissions EN55011 Class B Interference resistance EN 61000 6 2 Power supply Non replaceable lithium battery lifetime approximately 8 years...

Страница 8: ...INP B BL No 8 BL Backlighting 0 V DC GND Table 2 Scope of delivery Digital display Clamp Front frame for screw mounting Panel cut out 50 x 25 mm Front frame for clamp mounting Panel cut out 50 x 25 m...

Страница 9: ...english Connections max 30 V DC BL BL INP A INP B n c n c GND 24 V DC 20 50 mA 1 2 3 4 5 6 7 8 n c BL BL INP A INP B n c n c GND 1 2 3 4 5 6 7 8 n c max 30 V DC 24 V DC 20 50 mA DC Type ISI36 011AX01...

Страница 10: ...liquides corrosifs de la vapeur chaude ou des substances similaires Lors de l installation veiller assurer un refroidisse ment suffisant de l appareil 1 5 Instructions de montage Retirer le cadre de f...

Страница 11: ...parasites EN 55011 Classe B R sistance aux parasites EN 61000 6 2 Alimentation Batterie au lithium non rempla able dur e de vie env 8 ans 20 C Temp rature de travail 10 55 C humidit relative 85 sans...

Страница 12: ...par vis D coupe d encastrement 50 x 25 mm Cadre avant pour fixation par trier D coupe d encastrement 50 x 25 mm Joint Instructions d utilisation Nota Ce produit comporte une batterie au lithium Ne pas...

Страница 13: ...V DC BL BL INP A INP B n c n c GND 24 V DC 20 50 mA 1 2 3 4 5 6 7 8 n c BL BL INP A INP B n c n c GND 1 2 3 4 5 6 7 8 n c max 30 V DC 24 V DC 20 50 mA Type DC ISI36 011AX01 Type DC ISI36 010AX01 fran...

Страница 14: ...ISI36 14 www baumer com Abmessungen Dimensions Dimensions Senkung Af3 DIN 74 Countersinking Af3 DIN 74 Fraisure Af3 DIN 74 1 Schalttafelausschnitt Panel cut out D coupe d encastrement...

Страница 15: ......

Страница 16: ...nningen Phone 49 0 7720 942 0 Fax 49 0 7720 942 900 info de baumerivo com www baumer com Irrtum sowie nderungen in Technik und Design vorbehalten Subject to modification in technic design Sous r serve...

Отзывы: