Manual_GXP5_417_Lift_EN.doc
29/41
Baumer IVO GmbH & Co. KG
04.05.11
Villingen-Schwenningen,
Germany
Object 6001
Lift Number
Subindex 0
Data Type
Unsigned 8
Access ReadWrite
Default 1
EEPROM Yes
Description
Lift number
Values 1
Object 6380
Operating Parameters
Subindex 0
Data Type
Unsigned 16
Access ReadWrite
Default 4
EEPROM Yes
Description Operating
parameters
Values
Bit 0 Rotating direction = 0
Æ
Clockwise; 1
Æ
Counter-clockwise
Bit 2 Scaling function = 0
Æ
Max. resolution; 1
Æ
Saved resolution
Object 6381
Resolution
Subindex 1
Data Type
Unsigned 32
Access ReadWrite
Default
2000h = 8192 = 13Bit
EEPROM Yes
Description
Number of steps per rotation is freely selectable.
!Offset value is reset when resolution is changed!
Values
1 - 8192
Object 6382
Preset Value
Subindex 1
Data Type
Unsigned 32
Access ReadWrite
Default 0h
EEPROM Yes
Description
Freely selectable position value. Preset and internal position result in
offset (
Æ
Object 63C9h)
Values
0 - 536870911
Object 6383
Position in Steps
Subindex 1
Data Type
Unsigned 32
Access ReadOnly
Default
EEPROM No
Description
Current position incl. offset
Values
0 - 536870911