Manual_GXP5_417_Lift_EN.doc
19/41
Baumer IVO GmbH & Co. KG
04.05.11
Villingen-Schwenningen,
Germany
6384h
Encoder Meas. Step Setting
ARR
ro
Position of Unit 1
00h Largest
Subindex
U8
ro
03h
01h Measuring Step
U16
rw
64h 1 Unit of measuring step, multiple of 10 µm
02h Speed Measuring Step
U16
rw
0Ah 1 Unit of speed, multiple of 0.1 mm/s
03h Acceleration Measuring Step
U16
rw
0Ah 1 Unit of acceleration, multiple of 1 mm/s²
6390h
Speed Value Car
ARR
00h Largest
Subindex
U8
ro
04h
01h Position Unit 1
S16
ro
02h Position Unit 2
S16
ro
03h Position Unit 3
S16
ro
04h Position Unit 4
S16
ro
Speed
(see Object 6384 for unit)
63C0h Operating
Status
ARR
00h Largest
Subindex
U8
ro
04h
01h Position Unit 1
U16
ro
04h
02h Position Unit 2
U16
ro
04h
03h Position Unit 3
U16
ro
04h
04h Position Unit 4
U16
ro
04h
Bit0 = Rotating direction 0 = CW, 1 = CCW
Bit2 = Scaling Function 0 = off, 1 = on
CW = Increasing position value during clockwise
rotation (when viewing flange)
CCW = Increasing position value during counter-
clockwise rotation (when viewing flange)
63C1h Max.
Resolution
ARR
00h Largest
Subindex
U8
ro
04h
01h Position Unit 1
U32
ro
2000h
02h Position Unit 2
U32
ro
2000h
03h Position Unit 3
U32
ro
2000h
04h Position Unit 4
U32
ro
2000h
Maximum resolution in steps/rotation
63C2h Max.
Rotations
ARR
00h Largest
Subindex
U8
ro
04h
01h Position Unit 1
U16
ro
10000h
02h Position Unit 2
U16
ro
10000h
03h Position Unit 3
U16
ro
10000h
04h Position Unit 4
U16
ro
10000h
Max. number of rotations
63C4h Supported
Warnings
ARR
00h Largest
Subindex
U8
ro
04h
01h Position Unit 1
U16
ro
14h
02h Position Unit 2
U16
ro
14h
03h Position Unit 3
U16
ro
14h
04h Position Unit 4
U16
ro
14h
Following warnings are supported:
Bit2 = CPU watchdog status
Bit4 = Battery charge
63C5h Warnings
ARR
00h Largest
Subindex
U8
ro
04h
01h Position Unit 1
U16
ro
00h
02h Position Unit 2
U16
ro
00h
03h Position Unit 3
U16
ro
00h
04h Position Unit 4
U16
ro
00h
Following warnings are evaluated:
Bit2 = CPU watchdog status
Bit4 = Battery charge
63C6h Supported
Alarms
ARR
00h Largest
Subindex
U8
ro
04h
01h Position Unit 1
U16
ro
01h
02h Position Unit 2
U16
ro
01h
03h Position Unit 3
U16
ro
01h
04h Position Unit 4
U16
ro
01h
Following alarms are supported:
Bit0=Position error
63C7h Alarms
ARR
00h Largest
Subindex
U8
ro
04h
01h Position Unit 1
U16
ro
00h
02h Position Unit 2
U16
ro
00h
03h Position Unit 3
U16
ro
00h
04h Position Unit 4
U16
ro
00h
Following alarms are evaluated:
Bit0=Position error
63C8h Operating
Time
ARR
00h Largest
Subindex
U8
ro
4h
01h Position Unit 1
U32
ro
0h
02h Position Unit 2
U32
ro
0h
03h Position Unit 3
U32
ro
0h
04h Position Unit 4
U32
ro
0h
Time in 1/10 hours since last Reset
63C9h Offset
Value
ARR
00h Largest
Subindex
U8
ro
4h
01h Position Unit 1
U32
ro
0h
02h Position Unit 2
U32
ro
0h
03h Position Unit 3
U32
ro
0h
04h Position Unit 4
U32
ro
0h
Offset calculated from Preset
Æ
6382 h