Manual_GXP5_417_Lift_EN.doc
28/41
Baumer IVO GmbH & Co. KG
04.05.11
Villingen-Schwenningen,
Germany
Object 2800
PDO1 Addition (Event Trigger)
Subindex 0
Data Type
Unsigned 8
Access ReadWrite
Default 0h
EEPROM Yes
Description
Event Trigger value determines how often same PDO value is
transmitted
Values
0 =
PDO counter is deactivated
Æ
constant transmission (time
basis from Event Timer)
1..n..255 = Same PDO value is transmitted n times
(time basis from Event Timer)