Operating Instructions
Temperature measurement
CombiTemp™
TFRH/N
RTD temperature sensor
8. Configuration
8.1 Configuring DFON touch screen
f
Tap on the display screen and hold until the menu button appears.
f
Press menu to start the con
fi
guration.
Example
f
Co
nfi
gure screen layout.
Display menu
Display setup
Screen layout
Select display design
FlexTop specific screens
Menu
Further possible settings:
Relays
Warning and error indication
Screen layout
Color
Language
8.2 Configuring transmitter via DFON touch screen
For TFRH/N with mounted FlexTop™ 2212 and FlexTop™ 2222 transmitters further con
fi
gurations can be
programmed via DFON touch screen.
f
Tap on the display screen and hold until the menu button appears.
f
Press menu to start the con
fi
guration.
Example
f
Con
fi
gure input range.
Input config.
Input range
Input at 4 mA
Input at 20 mA
Temp. value
Temp. value
FlexTop menu
Menu
f
Co
nfi
gure damping range.
FlexTop menu
Menu
Output config.
Output damping
Damping value
Further possible settings:
Sensor type
Temperature unit
Output limit
Sensor offset
8.3 Configuring transmitter via FlexProgram
DANGER
FlexProgrammer is not ATEX approved for use in explosive atmospheres
f
Do not use FlexProgrammer in explosive atmospheres.
Configuring with FlexProgrammer and PC
f
Remove front cover/DFON display from TFRH/N.
f
Connect FlexProgrammer to FlexTop 2202.
f
Connect FlexProgrammer to PC and set
parameters (see FlexProgrammer instructions).
1
2
www.baumer.com
13 /
54