Adaptive trigger – hygienic/industrial
5.2 PL20H mounting
WARNING
Danger to health from contaminated medium
f
Only use weld-in sleeves or adapters from Baumer.
f
Do not seal process connections with Teflon tape (PTFE) or elastomer.
f
Welding work must only be carried out by welders trained in the area of hygiene.
PL20H with the following process connection:
G 1/2 A hygienic, BCID A03
9
Weld-in sleeve or adapter are hygienically
mounted and are internally flush.
9
Weld seams are smoothed out to Ra < 0.8 µm.
9
Leakage hole points downwards.
f
Screw in sensor.
Tightening torque: 15 ... 20 Nm
Example of mounting with weld-in sleeve ZPW3-321
1
1
1
2
1
ZPW3-321
2
Leakage hole
Example of mounting with weld-in sleeve ZPW2-326 or ZPW2-327
170°
5°
5°
5°
5°
190°
6 / 44