Operating Instructions
Level measurement
CleverLevel
®
PL20H/S
Adaptive trigger – hygienic/industrial
14.3 Window trigger
The window trigger is used to cause a sensor switch to react within a specific range, for example, in order
to isolate a specific medium. The switching window can be configured within a range from 0 … 100 %. The
window trigger is recommended for detecting and separating different layers, for example oil from water or
foam from beer.
Sweep Range (%)
Signal (%)
100
0
0
20
50
80
100
1
2
3
4
I
II
1
Good conductive medium
2
Adhesion from good conductive adhesive
medium
3
Oily medium
4
Air
Configuration example for a vessel that can be
filled with either a good conductive adhesive
medium (e.g. fruit preparation) or with an oily
medium (e.g. chocolate mix).
Switch windows I and II in this example are set to
achieve the following goals:
to detect the fruit preparation (1)
to exclude adhesion from fruit preparation (2)
to identify the chocolate mixture (3)
For more information, refer to the HELP menu in
FlexProgram.
Window trigger – Output setup
SW1 (NO) / SW2 (NO)
Factory setting
Switch window, min.
0%
Switch window, max.
75,3%
Switch window, hysteresis
2,4%
Damping
0,1 s
14.4 LED factory settings
LED-Funktion*
SW1
SW2
LED color
0
0
Green
1
0
Yellow
0
1
Cyan
1
1
Blue
Error
Error
Flashing red
Short circuit Short circuit
Red
Color examples
YE
GN
CY
BU
YE = Yellow: SW1 aktiv
CY = Cyan: SW2 aktiv
BU = Blue: SW1 und SW2 aktiv
GN = Green: SW1 und SW2 inaktiv
*1 = active, 0 = inactive
14 / 44