Baumer_EAM580_360_SAE_J1939_MA_EN_Rev0003.0000h_Index0002.docx
Baumer Electric AG
06.08.2018
25/27
Frauenfeld, Switzerland
10.2 Manufacturer Specific Profile Area
Ob
je
c
t
S
u
b
-In
d
e
x
Name
F
o
rm
a
t
Acc
e
s
s
Default
S
a
v
e
Description
2100h
Baudrate
U8
rw
2h X
0=10 kBit/s
1=20 kBit/s
2=50 kBit/s
3=100 kBit/s
4=125 kBit/s
5=250 kBit/s
6=500 kBit/s
7=800 kBit/s
8=1000 kBit/s
9=Autobaud
The baudrate is activated after a reset or power-on (if
parameter is saved to non volatile memory)
2001h
Electronic Gear
ARR
Configuration of electronic gear function
00h
Largest Subindex
U8
ro
3
01h
Enable
U16
rw
1 X
1 = electronic gear function disabled
2 = electronic gear function enabled
02h
Gear Value1
U16
rw
1 X
Numerator of the gear factor, Range 1…32767
03h
Gear Value2
U16
rw
1 X
Denominator of the gear
factor, Range 1…32767
2102h
ECU default address
U8
rw
ACh X
ECU Address. Address-
Range: 0 … 253
2103h
Group Extension PDU2
U8
rw
0h X
Group Extension, used for PDU2 (proprietary B)
2104h
PGN65450 Transmission Rate
U16
rw
32h X
Transmission Rate for PGN65450 [ms]
2110h
Feature control
U16
rw
0008h X
Bit 3: CAN Bus Off behavior
1 = Automatic CAN restarting
0 = Encoder behaves according obj. 1029h
2114h
Manufacturer Reserved
U32
rw
0
2117h
Encoder diagnostic
U16
ro, m
Encoder diagnostic bits
2118h
Speed [rpm]
S16
ro, m
Speed value of Encoder in [rpm]
2120h
Time stamp [us]
U16
ro, m
Time stamp in [us] of current position acquisition
2300h
Customer EEPROM
ARR
Customer EEPROM to save any data
00h
Largest Subindex
U8
ro
4
01h
CustomerEEPROM[0]
U32
rw
0 X
02h
CustomerEEPROM[1]
U32
rw
0 X
03h
CustomerEEPROM[2]
U32
rw
0 X
04h
CustomerEEPROM[3]
U32
rw
0 X
4001h
Speed sampling interval in ms
U16
rw
50 X
The speed sampling interval sets up the sampling interval
of the speed calculation
Range 1…500ms