Manual R600V.DAH5 Multi-object (EN)
Page 28 of 36
R600V.DAH5_multiobject_manual_1.1 (EN).docm
Address
Parameter
range
offset
scaling
Default value
0x07E394
Time to wait after sending a re-
quest for address claimed mes-
sage before own address claim is
sent
0..5000
0
1ms
1250
0x07E39D
Compare mask for “bitwise AND”
of ISO name used for Master ECU
Detection
0..0xffffffffffffffff
0
1
0
0x07E39E
Compare value for ISO name used
for Master ECU Detection (after
applying bitwise mask defined in
0x07E39D)
0..0xffffffffffffffff
0
1
0
0x07E395
Delay between detection of master
address claim and starting RUN
mode
0..5000
0
1ms
250
0x07E396
Delay between detection of master
address claim and first PDU1
transmission
0..5000
0
1ms
200
0x07E398
Lowest device address to claim in
address resolution sequence
128..209
0
1
128
0x07E399
Highest device address to claim in
address resolution sequence
128..209
0
1
209
0x07E39A
CAN Bus speed.
0 = 250k
1 = 500k
2 = reserved (do not use)
0..1
0
1
0
0x07EF40
Reset device to default values
Write data in this sequence to reset all non-volatile SPNs to default values:
0x00, 0xAA, 0x55, 0x12, 0x34
(4) Detection range can be adjusted to avoid issues with double echo detections.
(5) SPN value is reset to default after a power cycle (volatile)