Manual R600V.DAH5 Multi-object (EN)
R600V.DAH5_multiobject_manual_1.1 (EN).docm
Page 21 of 36
Supported PGN (Parameter Group Number)
3.3.1.
ECU Identification Info
PGN:
0xFDC5
Direction:
Transmit
Transmission rate:
On PGN request only
3.3.2.
ECU Software Identification
PGN:
0xFEDA
Direction:
Transmit
Transmission rate:
On PGN request only
3.3.3.
DM14 Memory access command message
PGN:
0xD900
Direction:
Receive
Transmission rate:
Random
3.3.4.
DM15 Memory access reply message
PGN:
0xD800
Direction:
Transmit
Transmission rate:
Reply to DM14 command message
3.3.5.
DM16 Memory access binary data
PGN:
0xD700
Direction:
Transmit/receive
Transmission rate:
When needed
3.3.6.
Object Messages (Main Messages)
PGN:
0xC000
Direction:
Transmit
Transmission rate:
50ms
Source address:
Sensor address
Destination address:
Broadcast (0xff)
Initial delay after start-up sequence:
200ms
All values are in little endian format. Bit1 of byte 1 = LSB of first byte