36
Troubleshooting
For common problems and solutions please see the table below.
This table should only be regarded as a general guide. Errors
and faults are relative to individual circumstances.
Fault Possible
causes
Solution
All the lights on
the command
panel are
blinking.
Overheating: circuit board
damage.
Turn the appliance off and wait for
about 15 minutes for it to cool
down and for the thermal
protection to be automatically
restored.
If, on switching the machine back
on, the same problem occurs call
the Baumatic Ltd Customer Care
Helpline to arrange for an engineer
to replace the power board.
The stop button
light is flashing
and an alarm is
sounding.
Insufficient vacuum in the
chamber. Minimum
vacuum power has not
been reached.
o
Lid not pressed down at the
start of the cycle.
o
Lid of the container badly
positioned.
o
Lid seal worn or badly
positioned.
o
A technician is required to
check the air circuit, the
sensor board and vacuum
pump.
o
A technician is required to
check the correct electro
valve opening.
o
Vacuum pump in thermal
protection state: switch the
appliance off and wait for
15 minutes.
When switched
on, all the LED’s
flash for 3
seconds and an
alarm sounds
Oil change warning due to
having reached 2500
cycles.
Technician required to change the
pump oil.
The cycle starts
but the pump
does not
Pump thermal protection
intervention due to
overheating.
Switch the device off and wait for
15 minutes before turning it back
on.
The appliance
will not switch
on
Energy shortage.
Check the electrical connection.
Low vacuum
level in the bag
1)
Irregular bag
soldering.
2)
Dirty or perforated
bag.
3)
Bag size not
suitable for the
size of the
product.
4)
Insufficient pump
performance.
1)
Position the bag correctly.
Check the state of the
Teflon cover. Technician
required to change the
Teflon and check the
soldering resistance.
2)
Change the bag.
3)
Choose a bag where the
volume of the product is not
more than 2/3 of the
volume.
4) Technician required to