Operating Manual for
BAUER Plug & Play Separator System
21
Separator - Forming the starter cake:
During commissioning and after servicing, if the separator screw was completely un-emptied, it is
necessary first of all, to build a plug in the separator press head. For this purpose please proceed as
described below using the "plug-forming aid".
1. Insert the plug forming aid in the press head, that inside-screw and outside-sieve is
sealed. (plug forming aid in the basic frame stowed)
2. Set the Operation choice switch on switch cabinet to
“HAND” (please refer fig.16)
3. Set the feed-pump switch on the remote control on position-
“FORWARD” to operate the
feed pump manually, until the separator inflow housing is completely filled
4. Switch on separator
5.
During separator-operation must be ensured that sufficient liquid is present in the inlet
housing, this is realized by temporarily on and off switching of the feed pump. This pro-
cess is repeated until the plug in the separator press head moves continuously forward.
Switch on remote control
FEED PUMP
REVERSE OFF FORWARD
Operation choice (on switch cabinet)
AUTO OFF HAND
Figure 16 OPERATION SWITCH
Figure 17 switch feed pump