ELECTRICAL CONNECTION
DANGER
Work on electrical and electronic components of the system may only be performed
by a trained electrician or otherwise appropriately trained personnel under the guid-
ance and supervision of a trained electrician in accordance with the applicable elec-
trical and electronic regulations.
WARNING
Fuses do not protect the motor from overloads; they only protect the electrical supply
lines or switching systems from damage in event of a short-circuit.
WARNING
Set the motor protection circuit breaker to the value specified on the motor type
plate ( I
Rated
/I
N
/I∆)
In forward motion, the screw shaft turns counterclockwise.
(As viewed from the discharge regulator toward the geared motor)
This can be checked with the phase monitoring relay
“1F2” in the switch cabinet:
Direction of rotation correct Indicator light is on (steady)
Direction of rotation incorrect: Indicator light is off
If the direction of rotation is incorrect, two of the
current-carrying
conductors “L1” and “L2” in the switch cabinet are swapped.
Viewing direction
Figure 6 rotation direction of the screw