Operating Manual for
BAUER Plug & Play Separator System
29
Troubleshooting
Fault
Cause
Remedy
Geared motor of a component
switches off
The motor switches off when the
permissible power consumption
of the motor has been exceeded.
The setting for the maximum
power consumption applies to
operation under load
1. Motor protection Separator
switches off (5 F1)
2. Motor protection clear Effluent
pump switches off (5F2)
3. Motor protection Belt conveyor
switches off (5F3)
4. Motor protection Oscillator
switches off (6F1)
5. Motor protection external fan Helix
switches off (6F2)
6. Motor protection Feeding pump
Helix switches off (7F1)
7. Overload
8. The setting for the maximum power
consumption is not adjusted cor-
rectly or the control unit has been
damaged.
9. Foreign bodies are blocking a com-
ponent
1. up to 7.
Check motor protection for correct
setting.
8. The switch-off limit should be ad-
justed again by a qualified electri-
cian according to the instructions
(see attached circuit diagram and
documentation)
9. Check Separator, Helix pump, Clear
effluent pump, Belt conveyor and re-
move foreign bodies
„important“
:
remove foreign bodies only when
cabinet is disconnected
Feeding pump does not start
when starting the system
1. Check motor protection
2. Feeding pump switches off after a
few minutes of operation
3. Feeding pump is delivering too
much material, Separator breaks
through
1. See troubleshooting: geared motor
switches off
2. Target pressure set too low.
3. Target pressure set too high.
Electrical cabinet currentless
1. Reset-lamp does not light up
2.
„Operation OK“ lamp does not light
up
3. Frequency converter does not
start
1. Check power supply line for cor-
rect connection and proper condi-
tion.