1
2
3
4
1
SteriPEN™ Adventurer/Traveler treats two ranges
of water volume:
A
—up to 0.5 liter (16 fl. oz.)
B
—between 0.5 – 1.0 liter (16 and 32 fl. oz.)
1
Install two CR123 batteries with polarities as shown.
2
Tighten coin screw on battery end cap until snug (do
NOT over-tighten screw as this may cause damage).
3
Remove lamp cover in 2 steps–1) Hold device as
shown and gently "bend" upward until lamp cover
releases with a click. 2) Remove lamp cover.
4A
Push On button
twice
– green LED will flash for up to
15 seconds indicating Adventurer/Traveler is ready to
treat up to .5 liter (16 fl. oz.).
NOTE:
Adventurer/Traveler
will not function unless this step is completed before
immersing lamp in water.
4B
Push On button
once
– green LED will flash for up to
15 seconds indicating Adventurer/Traveler is ready to
treat up to 1 liter (32 fl. oz.).
NOTE:
SteriPEN
™
Adventurer/Traveler will not function unless this step
is completed before immersing lamp in water.
5
While green LED flashes the ready signal,
dip the
ultraviolet (UV) lamp into the water to be treated so
that lamp and water sensors are completely
immersed. When water is detected, lamp turns on
automatically, emitting both UV and visible light.
IMPORTANT NOTE:
If visible light is not evident,
Adventurer/Traveler lamp is not on, and water should
not be consumed.
6
Agitate the water by stirring with the
Adventurer/Traveler until the lamp automatically
turns off. Once lamp turns off, green indicator LED
will turn on to show that the UV dose is complete.
NOTE:
If red LED turns on after lamp shuts off, the
dose was not complete.
7
Remove Adventurer/Traveler from water. Dry off lamp
and water sensors with clean cloth. Replace lamp cover.
IMPORTANT NOTE:
Many brands of CR123 batteries
have built-in protection circuitry that instantly disables
battery function when batteries reach a specific low
charge threshold. If this “disable” function is triggered
during operation the Adventurer/Traveler will be
unable to give the “Low Battery” signal (blinking red
LED). Until batteries are replaced or recharged the
Adventurer/Traveler will not be operational.
5
6
7
2
Safety
SteriPEN™ Adventurer/Traveler may be used in glass, plastic,
ceramic or metal containers. They all absorb and reflect UV light,
thereby shielding the user from UV exposure. Adventurer/Traveler
should not be used in quartz containers. The air/water interface
at the top of any drinking container is highly reflective to UV and
reflects UV back into the container.
SteriPEN™ Adventurer/Traveler User’s Guide
Your passport to safe
drinking water anywhere
™
Adventurer/Traveler
How does SteriPEN™ Adventurer/Traveler
disinfect water?
SteriPEN™ Adventurer/Traveler uses short wave germicidal
UV light to disinfect water. This range of UV light disrupts the
DNA within bacteria, viruses and protozoa, rendering them
unable to reproduce and therefore, harmless. For more
detailed information, visit our web site at ww.steripen.com.
Testing
At Hydro-Photon, we believe that careful testing is an important
part of successful and responsible product development and
quality control. A wide range of testing has gone into development
and production of your SteriPEN™ Adventurer or Traveler. To see
our full microbiological test reports conducted at the University
of Arizona, Tucson; University of Maine, Orono; Ryerson University,
Toronto Ontario; A&L Laboratory, Auburn, ME; and Oregon Health
Sciences University, Portland, visit the “Testing”section of our
web site at: www.steripen.com/testing.html.
Product Quality
At Hydro-Photon, product quality is our first priority. Every sin-
gle SteriPEN™ is tested for correct function and ultraviolet light
output. A Limited Lifetime Warranty for any manufacturing
defect is included with every SteriPEN™.
Thank you for buying your SteriPEN™ Adventurer or SteriPEN™
Traveler, and congratulations on your purchase. Years of careful
research, development and testing have gone into the creation
of this unique product.
Directions for Use
40 C.F.R. §156.10(i)(2)
It is a violation of Federal law to use this product in a manner
inconsistent with its labeling.
40 C.F.R. §156.10(i)(2)(ii)
SteriPEN™ exceeds U.S. EPA Guide Standard and Protocol for
Testing Microbiological Water Purifiers, destroying over
99.9999% of bacteria, 99.99% of viruses, and 99.9% of protozoa
when used as directed. SteriPEN™ is not a sterilizer.
Operating the SteriPEN™ Adventurer/Traveler
Quick Start Guide
Use SteriPEN
™
Adventurer/Traveler with clear water. Discolored or dirty water
should be pre-filtered until clear prior to SteriPEN™ Adventurer/Traveler treatment.