BE1-GPS100 

ORDERING 

SAMPLE STYLE NUMBER 

The style number identification chart defines the electrical characteristics and operation features included in 

BE1-GPS1 00  relay.  If the style  number were 

BE1-GPS100 E3N1 HOU, 

the device would have the following: 

(E) 

5  Amp nominal  system with  5  Amp  Independent  Ground  Input 

(3) 

Three  phase  voltage  sensing 

(N) 

Not  applicable 

(1) 

48/125VacNdc power  supply 

(H) 

Half  Rack  drawout  case 

(O) 

ASCII  Communications 

(U) 

Battery  backup  for real  time clock 

BE1-GPS100 

D D DD DDD 

CURRENT SENSING 

INPUT TYPE 

A) W/0 Independent Gnd Input 

B) 1 Amp  Independent Gnd  Input 

Nominal 

D) W/0  Independent Gnd Input 

E) 

5 Amp Independent Gnd Input 

F) 

1 Amp Independent Gnd Input 

&, 

VOLTAGE SENSING 

INPUT TYPE 

3) 3-phase sensing 

4)  3-phase sensing 

with independent 
auxiliary  input 

&&, 

COVER 

A) S1 cover with 

opening for  full 
HMI  access 

B) S1  cover with 

reset access 
only 

N)  Not  applicable 

(H1 case) 

POWER 

SUPPLY 

1)  48/125Vac/dc 

2) 125/250Vac/dc 

3) 24Vdc 

CASE 

RS-485 PORT 

PROTOCOL 

O)ASCII 

� 

1) 

Modbus'" 

ffi 

2)TNP 

3) DNP 3.0 

H)  H1 (Half  rack) 

NOTES: 

S)  S1 

ffi 

ffi. 

If  case option is H,  Cover option must be  N . 

.ffi 

Case option must be H for  Current Sensing Input Type  B, 

E, 

or 

or voltage sensing option  to  be 4. 

� 

ASCII  communication is standard on  ComO  (fron1  RS-232)  and Com1  (rear RS-232) ports. 

ffi 

Check  with factory  for availability. 

ffi 

Aux 

VT 

input adds 25 Sync-Check option. 

,®. 

Option  available in  H1  case only. 

STANDARD  ACCESSORIES 

OPTION 1 

N)  None 

U) 

Battery  Backup 

for Real Time 
Clock 

918 0400108 
92399221 00 
91 08 551 02 1  
91 08 550122 

H1  Test Case with 1 CT Terminal  Block and 18 - position  Bottom Terminal  Block 

Test box to facilitate bench testing. 
Adapter plate to  mount  an S1  case in aGE  S2  or Westinghouse FT-21  cutout. 
Adapter  plate to  mount  an S1  case in a Westinghouse  FT- 32  cutout. 

928 99 00017 

Escutcheon  plate 

to  panel mount 
one  H1  relay. 

928 99 0001 6  

928 99291 00 

Adapter bracket with  cutout 

for ABB FT  test  switch,  to 
mount a single  H 1  case in 
a 1 9" rack. 

928 992 41 00 

Escutcheon plate 

1" 

to panel mount two 

Adapter  b

acket  to 

dovetailed  H1  relays. 

I  II/ 

mount a smgle  H1 

lo 

case in a1 9"rack. 

'011 

§

®Basler Electric 

Figure  7A 

Cover  option A. 

Figure 

78 

Cover  option  B. 

ROUTE  143,  BOX 269, HIGHLAND,  ILLINOIS  U.S.A.  62249 

P.A.E.  Les  Pins,  67319  Wasselonne Cedex  FRANCE 

PHONE 618-654-2341  FAX 618-654-2351 

PHONE  (33-3-88)  87-1010  FAX  (33-3-88) 87-0808 

http://www.basler.com,  [email protected] 

Printed  in  U.S.A. 

www 

. ElectricalPartManuals 

. com 

Содержание BE-1-GPS100

Страница 1: ...rrent input for those applications where this is required Includes frequency tracking and voltage restrained overcurrent for backup and cogenera tion applications Includes Real Time Clock with 8 hour...

Страница 2: ...ic Fuse loss detection 60FL protects against false trip due to loss of voltage sensing CONTROL Virtual breaker control switch controllable from both HMI and com ports 101 Four virtual selector switche...

Страница 3: ...1 Advanced HMI Human Machine Interface APPLICATIONS The BE1 GPS100 Generator Protection System provides three phase ground and negative sequence overcurrent voltage frequency reverse power loss of exc...

Страница 4: ...ing the protection control metering and status monitoring functions into a substation automation system The standard IRIG 8 port provides time synchronization from a master clock Real time metering pr...

Страница 5: ...and IG Used for Ground Differential Overcurrent CONTROL POWER CONTROL POWER NOTES BE1 GPS100 A6 POWER SUPPLY A7 B2 1 CONNECTIONS SHOWN ARE FOR USE WITH PRE PROGRAMMED LOGIC SCHEME LZ W 25 L Z W 25 PRO...

Страница 6: ...E ENABLE ____ NOTES 8KRSTATUS CONDITIONING OSCI EVENT TRIGGER l SEAL IN LOGIC J m 1 ABBREVIATED LOGIC SHOWN E G NOT SHOWN THAT 27P 81 181 ARE CONTROLLED BY BKR STATUS 2 60FL ONLY SHOWN FOR V014 ALSO A...

Страница 7: ...ulation Test for Electrical Relays Impulse and Dielectric Strength 2000Vac at 50 60Hz IEEE C37 90 1 1989 Standard Surge Withstand Cap ability Tests for Relays and Relay Systems Associated with Electri...

Страница 8: ...g 3 1shot retrig 4 oscillator 5 integrating 6 latch Made J v INI BLK Mode v INI BLK _ Mode 0 disable 1 enable INI BLK 62 TIMER 162 TIMER 262 TIMER BREAKER FAILURE BF VT FUSE LOSS 60FL 62 162 cJ 62 60F...

Страница 9: ...BKR r e _a SB LOGIC I _ COMMAND r CLOSED I____ r r RESET 1 I 1 TARGET I _ SG TARG L _ REPORTING SETTING 1 FUNCTION 1 4 __ r r RESET 1 I I ALARM I _ SA ALARM L _ REPORTING SETTING 1 FUNCTION 1 _I _4 __...

Страница 10: ...000 12 0 2747 0 1042 1 000 0 4375 0 028 0 8868 V1 5 4678 0 10814 1 000 2 0469 0 028 5 5000 V2 4 4309 0 0991 1 000 1 9531 0 028 5 8231 E1 7 7624 0 02758 1 000 2 0938 0 028 7 7500 E2 4 9883 0 0129 1 000...

Страница 11: ...Time Time Accuracy 1 Shot Non Retrig 1 Shot Retrig Integrating Latch 0 000 9999 Sec 0 5 or eye CURRENT PICKUP ACCURACY All 46 50 and 51 Phase andGround 5A 2 or S O mA Neutral and Negative Sequence 1A...

Страница 12: ...ent Sensing Input Type B E or F or voltage sensing option to be 4 ASCII communication is standard on ComO fron1 RS 232 and Com1 rear RS 232 ports ffi Check with factory for availability ffi Aux VT inp...

Отзывы: