Possible Malfunctions
117262
69 / 70
EN
8
Possible Malfunctions
Mögliche
The table below contains descriptions of possible causes and solutions to
malfunctions or errors during operation of the appliance. When malfunction cannot
be removed, contact the technical service.
At the temperature and time display on the control panel, the triggered alarms are
shown. The following alarms may be shown:
Alarm/Mess
age
Description
Situation
Solution
E000-
Oven
chamber
sensor
Oven chamber
sensor error
Thermal processing
interruption,
automatic operation
reactivation
Replace the oven
chamber sensor
E001-
Motor
protection 1
Motor alarm 1
Thermal processing
interruption,
automatic operation
reactivation
If alarm persists,
contact the service
company
E002-
Oven
chamber
safety
Oven chamber
thermal switch
Thermal processing
interruption,
automatic operation
reactivation
If alarm persists,
contact the service
company
E004-
Board
temperature
too high
Too high an
electronics
chamber
temperature
Thermal processing
interruption,
automatic operation
reactivation
Check ventilation, air
filters, operation of
fans and components
E005-
Main control
board
—
control panel
communica-
tion
Communication
error between main
control board and
control panel
Thermal processing
interruption
Disconnect the
appliance from mains
power supply.
If alarm persists,
contact the service
company
Содержание Silversteam-K 6110DRS
Страница 1: ...Silversteam K 117262 117263 117264 117265...
Страница 17: ...Technical Data 117262 15 70 EN 4 2 List of Components of the Appliance Fig 1...
Страница 32: ...Operating Instruction 30 70 117262 EN Start screen Fig 8...
Страница 44: ...Operating Instruction 42 70 117262 EN Saving Thermal Processing Program Fig 21...