Installation Instructions
22 / 70
117262
EN
Connection to the cleaning agent tank
• To correctly run the wash process, the
appliance must be connected to the
cleaning agent tank.
• Enter the white cleaning agent tube into
the tank. The tube is located at the
bottom, left hand side of the appliance
(Fig. 6).
Fig. 6
Electrical Connection
• Before connecting the appliance to the power supply, make sure that voltage
and frequency values on the rating plate are conforming to the existing electric
installation. Connect the appliance only if the above mentioned parameters are
consistent with each other!
The allowable voltage deviation is ±10%.
• In order to directly connect the appliance to electrical supply, install an
automatic breaker between the appliance and the electrical installation, suitable
for the power value. Follow installation indications, so that contacts of such an
mechanism must feature suitable spacing, providing for full discharge with
respect to conditions for overvoltage category III. The disconnecting mechanism
should be installed so that it is available for the operating personnel all the time.
• The main switch, to which the plug of the mains power cord is connected,
should be set to '0' (zero) position. Have a qualified personnel check if the cord's
section is suitable for the power consumed by the appliance.
Содержание Silversteam-K 6110DRS
Страница 1: ...Silversteam K 117262 117263 117264 117265...
Страница 17: ...Technical Data 117262 15 70 EN 4 2 List of Components of the Appliance Fig 1...
Страница 32: ...Operating Instruction 30 70 117262 EN Start screen Fig 8...
Страница 44: ...Operating Instruction 42 70 117262 EN Saving Thermal Processing Program Fig 21...