6. SERVICE INFORMATION
LL= flashing slowly
LV= flashing quickly
LA= alternate flashing
ON = steady light
1. Verify that the water supply valve is open, then plug in the
machine and switch on the main switch; the appliance starts-
up in automatic mode (fig.
g
) after having pressed the
ON/Off start button (fig.
2@
).
2. Verify that the water reaches the tray, the float stops the
water before the overflow and that there are no leaks in the
system and in the water channels. The normal level of water
inside the tray is about 5/10 mm from the upper edge (fig.
k
).
The level of water can be adjusted by rotating the microfloat
or the water sensor on the slot on the relative support after
having loosened fastening screw 1 (fig.
k
). This adjustment
must be implemented after having disconnected the power
supply.
3. Verify that there is no abnormal vibration due to loose screws.
4. Always stop the appliance before implementing any operations
to resolve water leaks, tighten screws, etc.
5. Verify an ice production cycle ensuring that the cubes are
conveyed into the container.
6. Verify that the container sensor functions properly: place an
ice cube on the bulb inside the container; the appliance
should stop within 1 minute and restart automatically shortly
after removing it.
7. replace the cover previously removed.
THE FOLLOWING OPERATIONS MUST BE
IMPLEMENTED SOLELY BY OUR
QUALIFIED PERSONNEL
4. SIGNALS
5. OPERATING PROBLEMS
•
If the condenser overheats
The machine stops and only the air/water condensation remains in operation. The machine automatically restarts when the tem-
perature returns to below the limits set. Only after three consecutive alarms within a period of 5 hours, the machine turns off and
stays off.
•
Freezing cycle too long
In the case of three consecutive alarms within 5 hours, the machine stops.
Calculation of the maximum time of the freezing cycle:
1
st
cycle = 50'
2
nd
cycle = duration of 1 cycle x 1.5.
If the 1st cycle lasted less than 7' the maximum time of the next cycle will be 50'.
•
Defrosting too long
If the defrosting time is greater than 2 minutes and there are 2 consecutive failures within 5 hours, the machine stops.
•
Freezing cycle less than 7 minutes
The electronics calculate the cycle time as too long at 50 minutes.
•
Water loading too long
If the load time for the water is greater than 5' the machine stops in alarm. After a break of 120' the machine restarts automatically.
If water shortage is ongoing, the machine will attempt to restart every 120'.
function Status
Led 1
Green
Led 2
red
Notes
Machine ON
ON
Off
Applicable to all
conditions that are
not in alarm/error
Bin temperature
sensor error
Off
LL
Temperature sensor
out of range.
Machine Off
Condenser
temperature
sensor error
Off
LL
Temperature sensor
out of range.
The machine
continuous to run
Error cold cycle too
long or defrosting
too long
ON
ON
Machine Off
Condenser
overheating error
Off
ON
Machine Off
No water error
LL
ON
The signal is triggered
after attempting to restart
Maintenance
warning
LA
LA
The pre-set number of
operating hours has been
reached. The machines
continous to run
wash / clean
LV
LV
Signalled during the wash
routine
Start stand-by
LV
Off
waits to start after
switch-off