Water treatment 

 
 
Faster washing and saving costs 
 
Scale in the devices, spots on dishes or cutlery and smudges on glass are usually due to 
improper water quality. Salt leaves smudges or causes scale formation. 
 
Apart from an increased amount of time it will also increase the costs of: 
 

  equipment repair  

  device maintenance  

  staff  

  additional consumption 

 
Our device for water treatment makes descaling unnecessary; it also uses less washing liq-
uid and rinse. The system protection ensures the durability of the device, fewer failures and 
repairs. 
 
 
Scale formation protection 
 
Scale deposition 

Calcium and magnesium salts deposit in devices or on surfaces 
primarily in heated water. Formed scale formation hinders perform-
ance of a device or instrumentation and leaves undesirable resi-
due. 

 

 

Increased consumption 
reduced  

The consequences of scale deposition are: increased consumption 
of washing detergents or energy as well as the use of chemicals 
and the related negative consequences for the environment. That is 
why water treatment in households is recommended, in particular 
where a large amount of hot water is used for cleaning. 

 

 

Water softening 
 
System protection 

Softened water protects and reduces machine breakdowns, en-
sures longer maintenance cycles and saves the costs of servicing, 
material, repair and washing detergent. This solution becomes a 
part of the system protection. The device does not allow achieving 
an optimal effect of washing dishes without spots and smudges on 
glass. For this reason apply the product GAHOtech clean. 

 
 

 

Содержание GAHOtech soft MC-N 16

Страница 1: ...Location of installation Please read the operating manual before startup The manufacturer is not responsible for malfunctions caused by faulty operation and failure to comply with the provisions of t...

Страница 2: ...allation 7 2 1 Installation preparation plan 7 2 2 Dismanteling and utilization 7 3 Installation 8 4 Startup 8 5 Maintenance and service instructions 10 6 Troubleshooting 10 7 Spare parts 11 8 Product...

Страница 3: ...ible for any damage caused by water 9 The proper name and serial number of the device must be provided with any enquiries and ordering of spare parts Only then an effective and quick reply or order im...

Страница 4: ...ted water Formed scale formation hinders perform ance of a device or instrumentation and leaves undesirable resi due Increased consumption reduced The consequences of scale deposition are increased co...

Страница 5: ...e for dishwashers with soft water 0 dH total hardness or to the desired hardness level System structure manifold optional connections set optional water softening device 1 2 Device operation The optio...

Страница 6: ...roperly opened see figure on page 9 By turning a screwdriver counter clockwise increase the amount of tap water in the soft wa ter Check the water hardness in the regulated soft water 1 4 Technical de...

Страница 7: ...nd waste management Installation preparation plan for the purchaser Project The set includes manifold optional connections set optional water softening device dimensions width 310 mm depth 520 mm heig...

Страница 8: ...heck and tighten all fittings connecting the device Connect to electric power 4 Start up By the technical support personnel The device is factory adjusted The fine tuning is done by technical support...

Страница 9: ...e dial counter clockwise until the actuator is released and the drain valve is closed the valve is now back in the service position Set the time of day In order to do this slowly turn the programme di...

Страница 10: ...cloth The attached product card should also be regularly filled in Only then adequate mainte nance is provided 6 Troubleshooting Malfunction Cause Solution The device is not re sponding a Interrupted...

Страница 11: ...ing device b Clean the valve and add clari fier to the resin layer Regen erate more frequently c Valve inlet blocked by for eign bodies that dissolved in the pipes during previ ous works performed rel...

Страница 12: ...roduct card Client s address Number of hard water litres 16000 Total hardness Efficiency Hardness Date Salt tablets veri fied supplemented Pre filter op tional re placed Water hardness utility water W...