PAGE - 10 -
5. Maintenance and service instructions
•
The brine tank of the water softening device must always be filled with salt tablets. There-
fore it is necessary to ensure a supply of tablets.
•
Manual regeneration of the water softening device must be conducted periodically in order
to verify control techniques.
•
Problems occur if a filter candle is closed.
•
The membrane should be flushed from time to time. This operation can be performed only
by the manufacture’s authorized and qualified personnel. For this reason we recommend
signing a maintenance contract.
•
Once to twice a year rinse the accumulator with a moist cloth.
•
The attached product card should also be regularly filled in. Only then adequate mainte-
nance is provided.
6. Troubleshooting
Malfunction
Cause
Solution
The device is not re-
sponding.
a)
Interrupted power supply
to the device.
a) Provide a constant power
supply (check the fuse, plug,
driving chain or switch).
b)
Fault of the programmer.
b) Replace the programmer.
c)
Power supply malfunction. c) Reset the time of day.
The device is providing
hard water.
a)
The bypass valve is open. a) Close the bypass valve.
b)
No salt in the brine tank.
b) Add salt to the brine tank and
maintain the salt level above
the water level.
c)
Blocked injector or filter.
c) Replace injector and filter.
d)
Insufficient water flow to
the brine tank.
d) Check the time of filling the
brine tank and if required
clean the blocked supply pipe
of the brine tank.