PAGE - 11 -
Malfunction
Cause
Solution
The device is providing
hard water.
a)
Leakage in the manifold.
a) Inspect the manifold for pos-
sible crack. Control the O-ring
and the pipe.
b)
Inner leakage in the valve. b) Replace seals and spacing
components and/or piston.
The device is using too
much salt.
a)
Improper salt setting.
a) Check salt usage and salt
settings.
b)
Too much salt in the brine
tank.
b) Clean the outlet valve.
Water pressure drop.
a)
Iron deposition in the sup-
ply pipe of the water sof-
tening device.
a) Clean the supply pipe of the
water softening device.
b)
Iron deposition in the water
softening device.
b) Clean the valve and add clari-
fier to the resin layer. Regen-
erate more frequently.
c)
Valve inlet blocked by for-
eign bodies that dissolved
in the pipes during previ-
ous works performed relat-
ing to the installation of the
system.
c) Remove the piston and clean
the valve.
Iron in the softened water.
a)
Faulty resin layer.
a) Check backwash, brine suc-
tion and brine tank filling. In-
crease the frequency of re-
generation.
Too much water in the
brine tank.
a)
Outlet valve blocked.
a) Clean the outlet valve.
Additional instructions are available on the helpline.
7. Spare parts
No. Options
1 Manifold 70°C
2 Control system 90°C
3 Connections set
Expendable parts
Salt tablets (25 kg - bag)
GAHOtech soft MC-N 16 set
4 Control head (z)
5 Plastic tank + base
6 Cation resin
7 Brine tank and brine valve