background image

 
 

 

14 

ENGLISH 

GB 

9.1. 

Minimum setting of the hob burner valve  

 
These  settings  are  required  only  if the connected 
gas  type  differs  from  the  factory  preset  and 
checked  gas,  after  switching  to  the  different  gas 
type.  

Before performing this setting check whether the 
gas pressure is compliant with the value of nominal 
pressure (see table in the appendices).  

Follow the instructions below.  

1. 

Close the gas cut-off valve. 

2. 

Pull the control knob (

A).

 

3. 

Unscrew  screws 

B

  and  remove  the  control 

panel (

C

). 

4. 

Slowly  move  the  button  from  position  (

7)

 

clockwise  to  the  minimum flow  position  (

D

(just  before  the  blockade).  Turn  the  screw 
(

D

)  counterclockwise  in  order  to  increase 

the gas flow. After setting tighten the screw. 

5. 

Finally  reinstall  the  control  panel  (

C

)  and 

control knob (

A

). 

 
 

 

 

 

 

9.2. 

Minimum setting of the oven burner valve  

 
These  settings  are  required  only  if the connected 
gas  type  differs  from  the  factory  preset  and 
checked  gas,  after  switching  to  the  different  gas 
type. 

Before performing this setting check whether the 
gas pressure is compliant with the value of nominal 
pressure (see table in the appendices).  
Follow the instructions below.  

1. 

Close the gas cut-off valve. 

2. 

Pull the control knob (

A

). 

3. 

Unscrew  screws 

B

  and  remove  the  control 

panel (

C

). 

4. 

Remove the injection nozzle 

D

 and replace 

it  with  the  one  suitable  for  used  gas  type 
(see  appendices).  After  setting  tighten  the 
screw. 

5. 

Finally  reinstall  the  control  panel  (

C

)  and 

control knob (

A

). 

 

 

 

 

 

 

 

After  completing  all  calibration  and 

settings, check the tightness of gas system 
and proper operation of the device.  

Make  sure  that  the  flame  is  stable  with 
minimum or maximum output pressure. 
When the setting is done, install the prepared 
seal and/or seal the adjustment screws. 

ID 09 

ID 13 

Содержание FA092M00

Страница 1: ...GS UND W ARTUNGSANW EISUNGEN INSTALLATION OPERATING AND MAINTENANCE NSTRUCTIONS MANUEL D INSTALLATION D UTILISATION ET D ENTRETIEN MANUALE DI INSTALLAZIONE USO E MANUTENZIONE MANUAL DE INSTALACI N USO...

Страница 2: ...ODIFICATIONS TECHNIQUES CI RISERVIAMO LA POSSIBILIT DI INTRODURRE MODIFICHE TECNICHE SE RESERVA EL DERECHO A INTRODUCIR MODIFICACIONES T CNICAS SUJEITO A ALTERA ES T CNICAS TECHNISCHE WIJZIGINGEN VOOR...

Страница 3: ...ing and unpacking 11 8 2 Installation service technician 11 8 3 Extraction of fumes 12 8 4 Installation of the appliance in a line 12 8 5 Gas connection service technician 12 8 6 Switching into differ...

Страница 4: ...nition of gas stove burners 7 Ignition of oven burners 7 Inspection 13 Installation 11 Installation of the appliance in a line 12 M Minimum setting of the hob burner valve 14 Minimum setting of the ov...

Страница 5: ...any other use is considered as the use not in compliance with the intended use The manufacturer is not liable for material damage or damage to person caused by misapplication or incorrect application...

Страница 6: ...mation or draw attention to essential data Caution warning Indicate important safety instructions You should acquire the proper conduct to prevent hazard against people health and safety or not to cau...

Страница 7: ...day that the protection devices are mounted correctly and operational 4 4 Rating plate The rating plate shown in the drawing is fixed directly on the device It includes all guidelines and information...

Страница 8: ...s than original or intervention into the appliance without the manufacturer s consent that may have altered the safety requirements 5 USE AND OPERATION 5 1 Description of the controls The elements con...

Страница 9: ...stove burner off position 1 B To put out the ignition flame rotate the control knob clockwise position 0 5 3 Ignition of oven burners A Press the control knob and turn it left while simultaneously pr...

Страница 10: ...e of activation may lead to unexpected situations endangering the safety and health of people 6 2 Proper maintenance Proper maintenance includes daily cleaning of all components which have contact wit...

Страница 11: ...and replace all elements Protect the interior of the gas stove burner against water and dirt to avoid malfunction and clogging of nozzles 6 4 Cleaning of the oven When the oven is cold remove bottom...

Страница 12: ...e pipes in connection with the long downtime The igniting flame continuously goes out The thermal element is not sufficiently hot Extend the ignition process The ignition flame burns but the igniter d...

Страница 13: ...carton box It may damage the stainless steel inside the box Remove the carton packaging from bottom to top When unpacked check if the appliance is according to the order In case of any difference inf...

Страница 14: ...cted in such way that lock of suction fan interrupts the gas supply Installation of stoves of type A does not envisage connection to the fume exhaust system but to the appropriate extraction hood whic...

Страница 15: ...apply a new sticker which includes used gas type item 4 of the rating plate 8 7 Inspection service technician Before starting the device the installation check up should be run to evaluate the working...

Страница 16: ...mum setting of the oven burner valve These settings are required only if the connected gas type differs from the factory preset and checked gas after switching to the different gas type Before perform...

Страница 17: ...ipe F When required replace the nozzle G with a nozzle intended for used gas see appendices Tighten the screw E and restore the initial settings 9 4 Replacement of the ignition flame nozzles of the ga...

Страница 18: ...w C and set the Venturi pipe D Tighten the screw C and restore the initial settings 9 6 Replacement of the ignition flame nozzle of the oven burners Follow the instructions below Close the gas cut off...

Страница 19: ...roduct or attached manual indicates that the product cannot be considered as ordinary household waste and should be transferred to a special collection point for electrical and electronic appliances f...

Страница 20: ...I ANLAGEN ATTACHMENTS ANNEXES ALLEGATI ANEXOS ANEXOS BIJLAGEN ZA CZNIKI...

Страница 21: ...II...

Страница 22: ...emador Horno Consumo de gas Modelo Queimador Forno Consumo de g s Model Brander Oven Gasverbruik Model Palnik Piekarnik Zu ycie gazu 75 105 130 G20 G25 G30 G31 3 5 kW 5 kW 8 kW 8 KW kW m h m h kg h kg...

Страница 23: ...schluss R 1 2 UNI ISO 7 1 24 5 kW Gas Input Raccordement du gaz Allacciamento gas Conexi n Gas Liga o de g s Gasaansluiting Przy cze gazu ANSCHLUSSSCHEMA CONNECTION CARD FICHE DES RACCORDEMENTS SCHEDA...

Страница 24: ...1 2 UNI ISO 7 1 37 5 kW Gas Input Raccordement du gaz Allacciamento gas Conexi n Gas Liga o de g s Gasaansluiting Przy cze gazu ANSCHLUSSSCHEMA CONNECTION CARD FICHE DES RACCORDEMENTS SCHEDA ALLACCIAM...

Страница 25: ...schluss R 1 2 UNI ISO 7 1 32 5 kW Gas Input Raccordement du gaz Allacciamento gas Conexi n Gas Liga o de g s Gasaansluiting Przy cze gazu ANSCHLUSSSCHEMA CONNECTION CARD FICHE DES RACCORDEMENTS SCHEDA...

Страница 26: ...5 3 5kW ANSCHLUSSSCHEMA CONNECTION CARD FICHE DES RACCORDEMENTS SCHEDA ALLACCIAMENTI FICHA DE ENLACES ESQUEMA DAS CONEX ES PLAN AANSLUITINGEN SCHEMAT POD CZENIA Gasanschluss R 1 2 UNI ISO 7 1 45 5 kW...

Страница 27: ...1 90 40 21 Aperto Open G20 20 3 5 1 140 Reg Reg 8 CZ II2H3 G30 G31 28 37 3 5 1 90 40 21 Aperto Open G20 20 3 5 1 140 Reg Reg 8 DE II2ELL3B P G30 G31 50 3 5 1 80 40 21 8 G20 20 3 5 1 140 Reg Reg 8 G25...

Страница 28: ...I2H3B P G30 G31 30 3 5 1 90 40 21 Aperto Open G20 20 3 5 1 140 Reg Reg 8 SI II2H3 G30 G31 28 37 3 5 1 90 40 21 Aperto Open G20 20 3 5 1 140 Reg Reg 8 II2H3B P G30 G31 30 3 5 1 90 40 21 Aperto Open G20...

Страница 29: ...g Reg Aperto Open CZ II2H3 G30 G31 28 37 5 1 3 115 Reg 21 Aperto Open G20 20 5 1 3 165 Reg Reg Aperto Open DE II2ELL3B P G30 G31 50 5 1 3 100 Reg 21 Aperto Open G20 20 5 1 3 165 Reg Reg Aperto Open G2...

Страница 30: ...Reg Reg Aperto Open SE II2H3B P G30 G31 30 5 1 3 115 Reg 21 Aperto Open G20 20 5 1 3 165 Reg Reg Aperto Open SI II2H3 G30 G31 28 37 5 1 3 115 Reg 21 Aperto Open G20 20 5 1 3 165 Reg Reg Aperto Open II...

Страница 31: ...40 Reg 21 Aperto Open G20 20 8 2 8 205 Reg Reg 8 CZ II2H3 G30 G31 28 37 8 2 8 140 Reg 21 Aperto Open G20 20 8 2 8 205 Reg Reg 8 DE II2ELL3B P G30 G31 50 8 2 8 125 Reg 21 Aperto Open G20 20 8 2 8 205 R...

Страница 32: ...SE II2H3B P G30 G31 30 8 2 8 140 Reg 21 Aperto Open G20 20 8 2 8 205 Reg Reg 8 SI II2H3 G30 G31 28 37 8 2 8 140 Reg 21 Aperto Open G20 20 8 2 8 205 Reg Reg 8 II2H3B P G30 G31 30 8 2 8 140 Reg 21 Aper...

Страница 33: ...205 Reg 24 9 G30 G31 50 8 3 125 Reg 24 8 G20 20 8 3 205 Reg 24 9 G30 G31 28 37 8 3 145 Reg 24 11 G20 20 8 3 205 Reg 24 9 G30 G31 30 8 3 145 Reg 24 11 G20 20 8 3 205 Reg 24 9 G30 G31 28 37 8 3 145 Reg...

Страница 34: ...205 Reg 24 9 G30 G31 30 8 3 145 Reg 24 11 G20 20 8 3 205 Reg 24 9 Paese Land Pays Pais Land Categoria Kategoria Category Categorie Ugello bruciatore Brennerduse Burner nozzle Injecteurs du bruler Iny...

Страница 35: ...IE PT CH GR ES CZ 17 20 25 20 30 35 25 37 45 FR BE 17 20 25 20 25 30 20 28 35 25 37 45 LU 17 20 25 DE 17 20 25 17 20 25 42 5 50 57 5 42 5 50 57 5 AT CH 17 20 25 42 5 50 57 5 42 5 50 57 5 DK SE FI CZ S...

Страница 36: ...XVII NOTE...

Страница 37: ...QUESTO MANUALE CON DIVIETO DI RIPRODURLO E O DISTRIBUIRLO IN QUALSIASI FORMA SENZA NOSTRA AUTORIZZAZIONE DE ACUERDO CON LOS T RMINOS DE LA LEY EST RESERVADA LA PROPIEDAD DE ESTE MANUAL CON EXPRESA PR...

Отзывы: