13
ENGLISH
GB
If there are significant pressure differences in the
gas supply installation, it is recommended to
install a pressure regulator.
After the installation, check the gas connection for
tightness.
When looking for gas leaks do
not use the open flame!
8.6.
Switching into different gas type (service technician)
The
device
has
been
checked
by
the
manufacturer for the type of gas shown on the
rating plate. If a different type of gas is used,
follow these guidelines.
1.
Close the gas cut-off valve (
A
).
2.
Replace the nozzles of gas burners (see
section 9.3).
3.
Replace the nozzles of the ignition flames (see
section 9.4).
4.
Set the minimum value on the burners gas
valves (see section 9.1).
5.
Remove the sticker from the rating plate and
apply a new sticker which includes used gas
type (item 4 of the rating plate).
8.7.
Inspection (service technician)
Before starting the device the installation check-
up should be run to evaluate the working
conditions of every single component and
recognize any errors.
To check the
heating plate
it is recommended to
perform the following inspections:
1.
Open the gas valve and check the tightness of
connections;
2.
Check correct ignition and combustion of gas
stove burners;
3.
Check and adjust, if necessary, the gas
pressure and flow rate in Max and Min
positions (see section 9.1).
4.
Check if the safety thermostat operates
properly.
5.
Check gas lines for gas leaks.
9.
SETTINGS (service technician)
Before setting the device switch
on all protection devices.
First of all, close the gas valve and
prevent access to the device, which in
case of activation may lead to
unexpected situations endangering the
safety and health of people.
ID 12
ID 12
Содержание FA092M00
Страница 20: ...I ANLAGEN ATTACHMENTS ANNEXES ALLEGATI ANEXOS ANEXOS BIJLAGEN ZA CZNIKI...
Страница 21: ...II...
Страница 36: ...XVII NOTE...