Refrigerant metering device:
Capillary tube
Gas charge (R 134a)
Air cooled
Water cooled
F 80
300 gr
300 gr
F 125
400 gr
300 gr
Working pression
(with 21°C ambient temperature)
Pression
discharge
8÷9 bar
8÷5 bar
Pression
suction
0.5 bar
0.5 bar
Working pression
(with 21°C ambient temperature)
Pression
discharge
17÷18 bar
17 bar
Pression
suction
2.5 bar
2.5 bar
NOTE.
Before charging the refrigerant system
always check thetypeof refrigerantandquan-
tity as specified on the individual ice machine
dataplate. The refrigerant charges indicated
are relatives to averages operating condi-
tions.