14
Installation
2.
Position the Ethernet cable
towards the termination block.
Cable Positioning
ETHERNET AND POWER VERSION (ETH)
1.
Remove Ex e lid and
insert cables into glands
Unscrew the 7 M6x1 fasteners
and remove the Ex e lid to
access the power and network
interfaces.
Follow the mounting instructions
of the cable glands thoroughly.
3.
Cut cable insulation and
ethernet shielding according to
the illustrated values and add
cable ferrules.
Place the Ethernet cable shield in
contact with the shield clamp.
Cable Insulation cutting
Follow the cabling and termination instructions below for correct installation. Lay out the parts,
cables and components as shown in the illustrations. It's recommended to use the included
dome fixture during the cabling and termination process.
45 mm
35 mm
30 mm