12
Installation
2.
Position the Ethernet cable
towards the termination block.
Positioning the Ethernet
cable
POWER OVER ETHERNET VERSION (POE)
8.
Mount Ex e lid
Place the protective lid over
the Ex e chamber. Make sure
the Ex e gasket is properly
seated. Attach the 7 M6
fasteners. It is recommended
to use low- to medium
strength thread locking
sealant on all the 7 fasteners
1.
Remove Ex e lid and
insert cables into glands
Unscrew the 7 M6x1 fasteners
and remove the Ex e lid to
access the power and network
interfaces.
Follow the mounting instructions
of the cable glands thoroughly.
Follow the cabling and termination instructions below for correct installation. Lay out the parts,
cables and components as shown in the illustrations. It's recommended to use the included
dome fixture during the cabling and termination process.