Delivery mode
24
Aircraft Refuelling, Operating Instructions, BA 090323, (07.03.2022)
Select the line „Preset Quantity“ ant enter an appropriate quantity
When the preset quantity has been reached during the refuelling, the pump will automatically stop.
Configuration-dependent it may be allowed to continue refuelling after entering another preset quantity.
Confirm the message, if you want to continue refuelling, and enter the new preset quantity.
(Configuration: Sequence Controls Menu /Meter Controls Parameters/Preset Enter Retry)
The new preset quantity is added to the current amount. Upon reaching this amount, the pump stops
again automatically.
4.3.3 Large Display
After receiving the order, the order details will appear for review or modification. Alternatively, the
parameters aircraft registration, parking position status and a freely selectable parameter (here
transaction type) are now displayed in an enlarged view for better readability. The freely selectable
parameter can be selected using the selection buttons. You can edit the flight data using the "Edit flight
data" softkey, provided that a scheduled order can also be edited.
(Configuration: Sequence Controls Menu/Dialog Parameters/Enlarged display of flight)