Special functions
55
Aircraft Refuelling, Operating Instructions, BA 090323, (07.03.2022)
5.12 Switch off controller system
The system can also be switched off in the „Special Functions“ menu.
If the system is switched off via the "Special functions" window, the tour/shift will not
be ended.
5.13 Start flushing process
Depending on the configuration, the system will monitor the flushing interval of the hoses/meters and
blocks order processing after a certain length of time. Order processing will only be enabled again once
the corresponding hose/measuring point has been flushed. The flushing order is preassigned the
process type TU and a default quantity. The order fields cannot be changed. The configured flushing
volume of the hose is used as the default volume. The flushing order is stored in the tour journal.
If one hose must be flushed, fuel-filling with the second hose is not permitted.
Hose flushing is dependent on the two configuration settings in the sequence control
menu "Dialog parameters/Display of default data/ => "TOUR" and "Flushing the
hoses/flush function => ON".