background image

INSTALLATION INSTRUCTIONS

800.533.3948 

 www.barronltg.com 

4

40070002 REV 1 10/14

FBTCJ-24V

MOUNTING 

1. Suggested installation of FBTCJ-MC mounting clips is one every 8” for a straight run and as needed for a design. 

    Remember to never leave sections of the FBTCJ unsecured. 

2. The FBTCJ-LCH Linear Channel is designed for end-to-end installation in a continuous line.

3. Both the FBTCJ-MC and the FBTCJ-LCH can be mounted with counter sink screws (Hardware field supplied).  

    Verify screws are completely tightened or they may cause the FBTCJ to bunch up during insertion. 

4. Starting at the power feed end, gently start inserting the FBTCJ into the mounting. Do not twist, pull or kink the 

    product during installation. 

5. Make sure the molded power connector is aligned with the orientation of the product. Do not pull or bend the 

    power cord in any direction. 

6. After the product has been installed, energize for testing. 

TROUBLE SHOOTING 

Product will not light 

• Verify that there is power to the receptacle feeding the product. 

• Check the GFCI and see if it is tripped. 

• Double check that the FBTCJ-FC power connector was installed into the product correctly. 

• Check the transformer and ensure it has power. 

Product does not light for the first 3”- 4” 

• Product was cut incorrectly. It will be necessary to re-cut the product at the correct designated location and    

  reassembled. 

Product has a dark section in the run. 

• During installation, product was pulled, twisted, kinked and the interior circuitry was damaged. Either new product 

  will need to be cut, or the damaged section can be cut out and splice in a new section.

  

Содержание Speciality LED FBTCJ-24V

Страница 1: ...not twist pull or kink the product Do not operate if outer jacket is damaged or there are loose connections Inspect periodically for damage Do not secure with staples nails or like means that can damage the insulated PVC housing Do not install in locations where it is subject to continuous flexing Do not operate in temperatures exceeding 113 F 45 C Ground Fault Circuit Interrupter GFCI protection ...

Страница 2: ...ulling the internal circuitry while making the cut Stretching or pulling the product can result in damage 4 Install power connector to the end of the FBTCJ FC 24V Be sure to notice the orientation of product and the power connector The product has a right and left side The FBTCJ FC 24V power connector also has a Right and Left orientation To determine look at the cut end of the product and the ori...

Страница 3: ...roduct c Place 7 end cap against the product so that the screw holes are aligned with the mounting piece d Insert the screws in the 7 end cap holes tighten all four screws firmly to product 6 Do not energize until your front connector and your end cap have been installed completely 7 All transformers are IP67 rated Class 2 power supplies Install the transformer within 10 of the FBTCJ Connect the t...

Страница 4: ...installation 5 Make sure the molded power connector is aligned with the orientation of the product Do not pull or bend the power cord in any direction 6 After the product has been installed energize for testing TROUBLE SHOOTING Product will not light Verify that there is power to the receptacle feeding the product Check the GFCI and see if it is tripped Double check that the FBTCJ FC power connect...

Отзывы: