Annuncicom IC User Manual Version 01.20
Page
12
7.5
I / O settings
These settings adjust the device behavior for inputs and
outputs (attached buttons, the serial RTS/CTS signal and
the relay pulse duration).
Command Broadcasting
Configures the execution behavior of command
"r=c=XX".
When in
"compatibility mode" the command will be issued
as a UDP broadcast unconditionally. When set to
"secure
mode" the command will be issued only if a communication
with another device has taken place (in the last 2 minutes).
The command will be sent to that device only! Use the
"secure mode" when setting up multiple door stations
wired to door strikes.
Init Sequence
Enter one or more commands that will be executed on
start up (power on or reset).
I0
pushed command
Configures which command should be issued when the
I0
button is pushed (see further below for commands).
I0
released command
Configures which command should be issued when the
I0
button is released (see further below for commands).
I1
pushed command
Configures which command should be issued when the
I1
button is pushed (see further below for commands).
I1
released command
Configures which command should be issued when the
I1
button is released (see further below for commands).
Relay pulse duration
Defines the amount of time (in tenths of a second) the
relay will be activated (the door strike will buzz) when the
"PULSEDOUT" command (c=80) is received.
CTS close command
Configures which command should be issued when the
CTS signal on the serial connector is activated (see further
below for commands).
CTS open command
Configures which command should be issued when the
CTS signal on the serial connector is deactivated (see
further below for commands).
RTS pulse duration
Defines the amount of time (in tenth of a second) the RTS
output will change when the "PULSERTS" toggle command
(c=95) is received.
Commands
Multiple commands can be added using the & (Ampersand)
character. They will be executed sequentially in the order
as they apear in the configuration field.
TALKING MODE
c=83 : Activate the talking mode
c=84 : Deactivate the talking mode
c=91 : Activate the forced talking mode
STREAMING
c=77 : Set destination Syntax :
c=77&entry=
x
&ip=
a.b.c.d
&port=
p
&type=
t
For x use 1 to 8 (Streaming destination 1 to 8)
a.b.c.d is the IP address to stream to
p stands for the port number to be used
For t use 0 (not used), 1 (Raw UDP) or 2 (Raw TCP)
Example:
c=77&entry=2&ip=192.168.0.100&port=3030&type=1 sets
the destination 2 to Raw UDP to IP 192.168.0.100 on port
3030
I/O
c=78 : Activate the relay
c=79 : Deactivate the relay
c=80 : Pulse the relay for the preset time
c=85 : Simulate the I0 button being pressed
c=86 : Simulate the I0 button being released
c=87 : Simulate the I1 button being pressed
c=88 : Simulate the I1 button being released
SERIAL
c=89 : Simulates the CTS Signal being activated
c=90 : Simulates the CTS Signal being deactivated
c=60 : Activates the RTS Signal
c=61 : Deactivates the RTS Signal
c=80 : Pulse the RTS Signal for the preset time