![BARIX Annuncicom IC Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/barix/annuncicom-ic/annuncicom-ic_user-manual_475052012.webp)
Annuncicom IC User Manual Version 01.20
Page
11
Trap Target IP Address
Enter the IP address of the SNMP trap destination.
Low Audio Level
Define the low audio level for the trap generation. A trap
will be generated as soon as the audio level goes below this
value (and the silence timeout is run out).
High Audio Level
Define the high audio level for the trap generation. A trap
will be generated as soon as the audio level goes above this
value.
Trap Repeat
Define the repeat interval for the SNMP trap sending. The
trap will be repeated if the values are still according to the
defined trap stages after this repeat time.
Silence Timeout
Define the time that has to run out before a trap is sent
when the audio level is below the defined low audio value.
Notes
The choice of settings to distribute the stream to the other
station(s) depends on your environment and desired
functionality.
If the reception of up to 8 streams need to be guaranteed
we recommend using TCP since lost packets are
retransmitted automatically.
If the stream is intended to be received by many devices
we recommend using UDP broadcast (as long as all devices
are on the LAN as broadcast is not passed over a WAN by
the routers).
If your network infrastructure is capable of multicasting use
multicast to reduce the traffic generated by broadcasting.
A mix of all the above is possible as each of the 8 destina-
tions allow an individual choice of connection type.