WALL MOUNT GENERAL INFORMATION
Heat Pump Wall Mount Model Nomenclature
W
30
H B –
A
10
X
X
X
X
X
A
NOTE:
Vent options X, B and M are without exhaust capability. May require separate field-supplied barometric relief in building.
Shipping Damage
Upon receipt of equipment, the carton should be
checked for external signs of shipping damage. If
damage is found, the receiving party must contact
the last carrier immediately, preferably in writing,
requesting inspection by the carrier’s agent.
General
The equipment covered in this manual is to be installed
by trained, experienced service and installation
technicians.
The refrigerant system is completely assembled and
charged. All internal wiring is complete.
The unit is designed for use with or without duct work.
Flanges are provided for attaching the supply and
return ducts.
These instructions explain the recommended method
to install the air cooled self-contained unit and the
electrical wiring connections to the unit.
These instructions and any instructions packaged with
any separate equipment required to make up the entire
air conditioning system should be carefully read before
beginning the installation. Note particularly “Starting
Procedure” and any tags and/or labels attached to the
equipment.
While these instructions are intended as a general
recommended guide, they do not supersede any
national and/or local codes in any way. Authorities
having jurisdiction should be consulted before the
installation is made. See page 3 for information on
codes and standards.
Size of unit for a proposed installation should be
based on heat loss/gain calculation made according
to methods of Air Conditioning Contractors of America
(ACCA). The air duct should be installed in accordance
with the Standards of the National Fire Protection
Association for the Installation of Air Conditioning and
Ventilating Systems of Other Than Residence Type,
NFPA No. 90A, and Residence Type Warm Air Heating
and Air Conditioning Systems, NFPA No. 90B. Where
local regulations are at a variance with instructions,
installer should adhere to local codes.
Duct Work
All duct work, supply and return, must be properly
sized for the design airflow requirement of the
equipment. Air Conditioning Contractors of America
(ACCA) is an excellent guide to proper sizing. All duct
work or portions thereof not in the conditioned space
should be properly insulated in order to both conserve
energy and prevent condensation or moisture damage.
MODEL NUMBER
CONTROL MODULES
(See Spec. Sheet S3592)
VOLTS & PHASE
A - 230/208/60/1
B - 230/208/60/3
C - 460/60/3
REVISIONS
VENTILATION OPTIONS
(See Spec. Sheet S3592)
X - Barometric Fresh Air Damper (Standard)
A - Fresh Air Damper w/Exhaust
B - Blank-Off Plate
D - Economizer, 0-10V no controls
M - Commercial Ventilator, ON/OFF
R - Energy Recovery Ventilator
S - Partial Flow Economizer, JADE
V - Commercial Ventilator,
0-10V variable
Y - Full Flow Economizer, DB
Z - Full Flow Economizer, JADE,
DB and WB
FILTER OPTIONS
X - 1" MERV2 Disposable Filter
W - 1" MERV2 Permanent Filter
P - 2" MERV8 Disposable Filter
M - 2" MERV11 Disposable Filter
N - 2" MERV13 Disposable Filter
COLOR & CABINET
FINISH
X - Beige Baked
Enamel Finish
1 - White Baked
Enamel Finish
4 - Buckeye Gray
Baked Enamel
Finish
5 - Desert Brown
Baked Enamel
Finish
8 - Dark Bronze Baked
Enamel Finish
S - Stainless Steel
A - Aluminum
COIL OPTIONS
X - Standard
1 - Phenolic Coated Evaporator
2 - Phenolic Coated Condenser
3 - Phenolic Coated Evaporator
and Condenser
4 - Coated Coils and Condenser
Section
5 - Coated Coils, Inside and
Outside of Unit
PLACEHOLDER
X - Future Use
CAPACITY
18 - 1½ Ton
24 - 2 Ton
30 - 2½ Ton
36 - 3 Ton
H - Heat Pump
SPECIALTY PRODUCTS
(Non-Standard)
KW
Insert “D” for dehumidification with hot gas reheat. Reference latest revision of Form 7960-828 for complete details.
For 0 KW and circuit breakers (230/208 volt) or toggle disconnect (460V) applications, insert 0Z in the KW field of the model number.