R9001440/9
GRAPHICS
TCR Adjustment procedure
Date:10/02/2000
6300
24
TCR Adjustment procedure
Adjust Field Flicker with + an -, then use X to exit.
Adjust Field Flicker G
+
: increase
-
: decrease
x : Exit
Input number 3 to proceed to measurement of the LCD transmission curves.
TCR procedure V1.30
Step 3: Measurement of LCD transmission curves
Continue (C) or Skip (S)
Input (C)ontinue starts the LCD transmission curves measurement.
Now
4 curves will be measured : red, green, blue and reduced green (green
video)
, each in 24 steps. (It is possible to skip each color if it was measured on a
previous run, when you type S at the start).
example: LCD transmission curve for Blue
Red (<return> to proceed, S to Skip, A for all)
Green (<return> to proceed, S to Skip)
Blue (<return> to proceed, S to Skip)
Reduced Green (<return> to proceed, S to Skip)
After the measurement, the results will be displayed in a graph. This graph shows
the S-shaped transmission curve, and a set of 8
g
-correction curves. For red, green
and blue, the transmission curve has a pronounced S-shape. The last transmission
curve (green video) should have a bent appearance, already more like a gamma
curve.
TCR procedure V1.30
Select
1. Input parameters
2. Green reduction
3. Measurement LCD transmission curves
4. Adjustment different color temperatures
5. Checking the color tracking
6.
7. Exit.
Step 3: LCD transmission