5. Installation
Barco - OV-508/OV-513/OV-515– R5990099 – installation manual – revision 01– November 2007 ________________________________
________________________________
________________________________
________________________________________________
________________
________________
________________ 17
Step 07
Subsequently install the two top horizontal profiles
PU II 3.
One of these profiles has three additional counter
nuts. This profile has to be installed at the front!
The counter nuts are used to install the angle with
the multi power strip!
5.3
Installation of the LAN interface and power strip
6
5
4
3
2
1
column
1
row
2
3
4
5
6
Schematic for cabling interfaces for the LAN switch:
Within a row (vertical direction!), each color represents
one switch (cabling interface). The column where to
install the cabling interface should be selected to
minimize distances between the respective projection
units and the cabling interface.
Not defined by the schematics: the row where to
install the cabling interface. To minimize distances, this
should be the mid row of a display wall!
Example 4x3 configuration:
2 cabling interfaces are required,
1x column 2, row 2
1x column 4, row 2
Step 08
The projection units are LAN enabled and thus have
to be connected to a LAN switch which is connected
to the LAN.
Always 6 projection units are connected to the
switch, all switches are cascaded.
Preferably the installation is done "per column", e.g.
in case the number of rows = 6, every column has to
be provided with a switch. This consideration results
in the schematic at the left
Look at the schematic at the left to define the
columns to be equipped with a cabling interface.
For these columns the angle with the multi power
strip has to be modified as explained below.