2. Installation requirements
2.1
Mechanical requirements of a suspended installation
Weight
Do not underestimate the weight of a complete NX
fi
xed display. Be sure that the truss installation on which the NX
fi
xed display has
to be installed is capable of handling
fi
ve (5) times the complete load of the display. Note that one NX
fi
xed tile weighs approximately
14 kg (or 72 kg per square meter display).
Truss beam
The truss beam has to be provided and installed by the customer because it varies from system to system. Although, the following
must be taken into account and must be precisely calculated on individual basis:
•
Weight tolerances
: Ensure that the truss beam and the ceiling against which the truss beam has to be installed, is able to
handle the complete weight of the NX
fi
xed LED display.
•
Environmental conditions
: Humidity, draught, temperatures, etc.
•
Location
: Indoor, altitude, etc.
•
Ceiling stability.
•
Front clearances
: For optimal impact ensure that there is suf
fi
cient free area in front of the NX
fi
xed display and respect the
minimum viewing distance.
•
Local regulations regarding such installations
.
W
ARNING
:
A suspended installation is limited to a height of 50 NX
fi
xed tiles.
Preparing a truss beam
For optimal use of the NX high precision frames and to obtain a high quality NX
fi
xed LED display, the customer has to prepare a
truss beam based on the hole pattern of the assembled NX high precision frames.
. . .
. . .
380 mm
68 mm
380 mm
380 mm
380 mm
380 mm
1
2
All tolerances 0.1 mm
+
-
Image 2-1
1
Mounting whole with small vertical margin zone (1.95 mm).
2
High precision mounting whole.
W
ARNING
:
The truss beam needs to have a
fl
atness tolerance of 0,1 mm.
10
R59770279 NX FIXED 16/06/2008
Содержание NX--4
Страница 1: ...NX fixed Installation manual R59770279 00 16 06 2008...
Страница 4: ......
Страница 6: ...Table of contents 2 R59770279 NX FIXED 16 06 2008...
Страница 12: ...1 Safety 8 R59770279 NX FIXED 16 06 2008...
Страница 24: ...2 Installation requirements 20 R59770279 NX FIXED 16 06 2008...
Страница 28: ...3 System overview 24 R59770279 NX FIXED 16 06 2008...
Страница 31: ...4 Components of a NX fixed tile Image 4 4 R59770279 NX FIXED 16 06 2008 27...
Страница 38: ...4 Components of a NX fixed tile Image 4 13 34 R59770279 NX FIXED 16 06 2008...
Страница 62: ...8 Basic procedures for a back access NX fixed display Image 8 8 58 R59770279 NX FIXED 16 06 2008...
Страница 66: ...8 Basic procedures for a back access NX fixed display 62 R59770279 NX FIXED 16 06 2008...
Страница 67: ...9 Maintenance 9 MAINTENANCE Overview Cleaning NX fixed tiles R59770279 NX FIXED 16 06 2008 63...
Страница 77: ...10 SERVICING Image 10 8 R59770279 NX FIXED 16 06 2008 73...
Страница 81: ...10 SERVICING Image 10 15 5 Remove the safety cable Image 10 16 R59770279 NX FIXED 16 06 2008 77...
Страница 86: ...10 SERVICING 82 R59770279 NX FIXED 16 06 2008...