4. Components of a NX fixed tile
G Power/Data output port 1.
H Positioning pin (each mounting plate has 4 positioning pins).
I
Power input socket (C14).
J
Mounting plate.
K
Fast screw.
L
Lock to open the NX control box.
M USB port for service purpose.
N NX control box door.
O Diagnostic LED’s.
W
ARNING
:
Barco uses HDMI connectors and cables, which allows a higher bandwidth for data communica-
tion between the NX control boxes and DX-700 digitizer. Nevertheless, Barco does not use the standard HDMI
protocol but their own communication protocol NNI (New Netebuk Interface). As a result the pin con
fi
guration
of the HDMI connector is different as well. Because of this never connect a device, having standard HDMI
input or output ports such as an LCD display or a DVD player, with an NX control box or a DX-700 digitizer.
Such a connection could be harmful for both Barco devices as for the standard HDMI devices.
W
ARNING
:
The NX control box may be mounted in all kind of directions except upside down.
Using the NX control box as stand alone re-sync unit
The NX control box acts like a stand alone re-sync unit in case no power is applied to the power input socket of the NX control box.
Maximum one stand alone re-sync unit can be placed between the digitizer and
fi
rst active control box. Maximum connect two stand
alone re-sync units in series between two active control boxes. The cable length between two NX control boxes may not exceed 5
meter.
The NX control box can only be used with the new generation of DX digitizers like the DX-700 digitizer.
Cables used with the NX control box
The following cables are used to link NX control boxes.
Image 4-9
Power cable.
Image 4-10
Data cable.
R59770279 NX FIXED 16/06/2008
31
Содержание NX--4
Страница 1: ...NX fixed Installation manual R59770279 00 16 06 2008...
Страница 4: ......
Страница 6: ...Table of contents 2 R59770279 NX FIXED 16 06 2008...
Страница 12: ...1 Safety 8 R59770279 NX FIXED 16 06 2008...
Страница 24: ...2 Installation requirements 20 R59770279 NX FIXED 16 06 2008...
Страница 28: ...3 System overview 24 R59770279 NX FIXED 16 06 2008...
Страница 31: ...4 Components of a NX fixed tile Image 4 4 R59770279 NX FIXED 16 06 2008 27...
Страница 38: ...4 Components of a NX fixed tile Image 4 13 34 R59770279 NX FIXED 16 06 2008...
Страница 62: ...8 Basic procedures for a back access NX fixed display Image 8 8 58 R59770279 NX FIXED 16 06 2008...
Страница 66: ...8 Basic procedures for a back access NX fixed display 62 R59770279 NX FIXED 16 06 2008...
Страница 67: ...9 Maintenance 9 MAINTENANCE Overview Cleaning NX fixed tiles R59770279 NX FIXED 16 06 2008 63...
Страница 77: ...10 SERVICING Image 10 8 R59770279 NX FIXED 16 06 2008 73...
Страница 81: ...10 SERVICING Image 10 15 5 Remove the safety cable Image 10 16 R59770279 NX FIXED 16 06 2008 77...
Страница 86: ...10 SERVICING 82 R59770279 NX FIXED 16 06 2008...