46 ______________________________________________________ Barco - NSL-4601 - User manual
Specifications
8.2.3
Packing
•
Drop test according to Barco specifications is performed on the overall pack-
ing.
•
Unit packing is one packing responding to standards of international trans-
port by air / sea / ground.
8.3
Environmental specifications
8.3.1
Storage temperature
•
High temp: +60°C (+140°F)
•
Low temp: -20°C (-4°F)
8.3.2
Operating temperature
•
High temp.: +40°C (+104°F)
•
Low temp.: +5°C (41°F)
8.3.3
Relative humidity operating
•
Operating: 20 to 80% non-condensing
8.3.4
Relative humidity storage
•
Storage: 10 to 90% non-condensing
8.3.5
Random vibration
•
0 - 0,0065 g²/Hz (5-500 Hz random, 1 hour/axes, 3 axis)
8.3.6
Requirement for dusty environments
The room in which the display unit is installed and operational must be dust-
free. The room must comply with a dust class of 8 or better according to
ISO14644-1. If the room in which the display unit is installed does not comply
with the dust class stated above, please contact Barco to discuss possibilities to
protect the display unit against dust.
NOTE
:
All construction, reconstruction, decoration activities must be completed before the installation
and operation of the product.
8.3.7
EMI /EMC
The units are designed to meet following standards:
•
USA:
3
FCC Class A (Part 15B)