RS232 Protocol NSL-4601
54 of 58
3.6.11
REPLY “NO SIGNAL”
This function is for return no signal status of current input source when input source is changed.
This is not available in all set or group selected.
Reply to PC
ID
(char-3~5Bytes)
Return Cmd
(char-4Bytes)
Data End
(char-2Bytes “\r\n”)
(0) MSG
\r\n
3.6.12
Read ETC setting status (only for single monitor)
This function is for updating current all etc menu setting status of selected one monitor. This is not
available in all set or group selected.
See 3.1.1 Read (only ONE SET selected)
3.7 Calibration
For know we can live with two different protocols for calibration and control. However it
would be desired to have one single protocol for this.
Maybe the functionality could be offered in both protocols?
3.7.1
Start Calibration Mode
1) Send to Monitor (for PC to Monitor 1:1)
Cmd
(Hexa-1Byte)
Length
(Hexa-1Byte)
Check Sum
(Hexa-1Byte)
0xE0 0x03 0xE3
Check Sum = Cmd + Length
2) Send to Monitor (for Cell in the Multi chain)
Cmd
(Hexa-1Byte)
Length
(Hexa-1Byte)
ID
(Hexa-1Byte)
Check Sum
(Hexa-1Byte)
0xE0 0x04 0x00 0xE4
Check Sum = Cmd + Length
3) Reply to PC
Ack
(Hexa-1Byte)