1. Preliminary Remarks
1.2.1.1
Connecting the device with the AC inlet
When connecting the device with the AC inlet, make sure that the power cords you use follow the specifications
mentioned below:
Mains lead (AC Power cord) with CEE 7 plug:
The wires of the mains lead are colored in accordance with the following code:
green
Earth (Ground)
blue
Neutral
brown
Line (Live)
Power cord with NEMA 5-15 plug:
The wires of the power cord are colored in accordance with the following code.
Green or Green/Yellow:
Earth (Ground)
White or Blue:
Neutral
Black or Brown:
Line ( Live)
•
The cord set must be UL-approved and CSA-certified.
•
The minimum specification for the flexible cord is No. 18 AWG Type SVT or SJT, 3-conductor.
•
The cord set must have a rated current capacity of at least 10A.
•
The attachment plug must be an Earth-grounding type with a NEMA 5-15P (10 A, 125 V) configuration.
Power cord with GB 2099 plug:
The wires of the power cord are colored in accordance with the following code.
green
Earth (Ground)
blue
Neutral
brown
Line ( Live)
Barco - KVD5521, IVD5521, HVD5521 - R591341 - User Manual - Revision 05 - November 2016
_______________________________________________________
13