6. Random Access
How to Start Up Edit WARP1 File?
1. Push the cursor key
↑
or
↓
to highlight
Edit WARP1
2. Press
ENTER
to select.
The Edit file adaptation menu will be displayed. (menu 6-10)
3. Select the file which must be edited (mostly the active file).
The file name will be displayed in the upper right corner. (menu 6-11)
FILE SERVICE
LOAD
EDIT WARP1
EDIT WARP2
RENAME
COPY
DELETE
OPTIONS
Select with
↑
or
↓
then <ENTER>
<EXIT> to return
Menu 6-9
EDIT FILE
Filename
Scr
resolution
xga_60.s01
1
1024x768
xga_60.c01
1
1024x760
xga_60.c02
1
1024x760
xga_60.c03
1
1024x760
----------------------------
Active file : xga_60.c04
Select with
↑
or
↓
,
→
<ENTER> to accept
<EXIT> to return
Menu 6-10
EDIT FILE xga_60.c02
HORIZONTAL
TOTAL
1344
PIXELS
ACTIVE
1024
PIXELS
START
266
PIXELS
PERIOD
16.625 µs
VERTICAL (FIELD)
TOTAL
800 LINES
ACTIVE
760 LINES
START
37
LINES
READ AMDS
OPTIONS
↑
,
↓
,
←
,
→
<ENTER>, <EXIT>
Menu 6-11
6.3.6
Edit WARP2
When available?
The Edit WARP2 adjustment is only available when a Stereo Image is projected, when projecting a Mono Image this item will be
grayed out in the
File Service
menu.
What can be done?
When a Stereo Image is projected, within this menu, it is possible to change the File Settings for the Right Image of a selected
source file.
How to Start Up Edit WARP2 File?
1. Push the cursor key
↑
or
↓
to highlight
Edit WARP2
2. Press
ENTER
to select.
The Edit file adaptation menu will be displayed. (menu 6-13)
3. Select the file which must be edited (mostly the active file).
The file name will be displayed in the upper right corner. (menu 6-14)
FILE SERVICE
LOAD
EDIT WARP1
EDIT WARP2
RENAME
COPY
DELETE
OPTIONS
Select with
↑
or
↓
then <ENTER>
<EXIT> to return
Menu 6-12
EDIT FILE
Filename
Scr
resolution
xga_60.s01
1
1024x768
xga_60.c01
1
1024x760
xga_60.c02
1
1024x760
xga_60.c03
1
1024x760
----------------------------
Active file : xga_60.c04
Select with
↑
or
↓
,
→
<ENTER> to accept
<EXIT> to return
Menu 6-13
EDIT FILE xga_60.c02
HORIZONTAL
TOTAL
1344
PIXELS
ACTIVE
1024
PIXELS
START
266
PIXELS
PERIOD
16.625 µs
VERTICAL (FIELD)
TOTAL
800 LINES
ACTIVE
760 LINES
START
37
LINES
READ AMDS
OPTIONS
↑
,
↓
,
←
,
→
<ENTER>, <EXIT>
Menu 6-14
6.3.7
Changing the settings
Different methods
The 3 different methods to change a setting will be described hereafter. These methods are:
•
with the numeric keys on the remote control.
•
with the arrow keys selecting the changing digit.
•
with the arrow keys counting up or down.
50
R5976755 BARCO GALAXY WARP™ 7 HC 05/04/2004
Содержание Galaxy WARP 7 HC
Страница 1: ...Barco Galaxy WARP 7 HC Owner s Manual R9040325 R5976755 00 05 04 2004...
Страница 4: ......
Страница 8: ...Table of contents 4 R5976755 BARCO GALAXY WARP 7 HC 05 04 2004...
Страница 36: ...4 Connections 32 R5976755 BARCO GALAXY WARP 7 HC 05 04 2004...
Страница 43: ...5 Getting Started Image 5 6 RCU to IR Sensors R5976755 BARCO GALAXY WARP 7 HC 05 04 2004 39...
Страница 122: ...6 Random Access 118 R5976755 BARCO GALAXY WARP 7 HC 05 04 2004...