Operation
62
User manual CCFD 2320
filters to filter possible high-frequent distortion from an
analog
video signal.
Select a different filter in case the image contains high-
frequent noise or distortion. Select the filter that gives
the best result.
Readjustment of sample phase is necessary after
selection of a different filter.
Advanced functions in the Settings menu
Display Function
See the Glossary section for more information about
display functions.
The display contains a number of factory-defined and
user-defined lookup tables (LUTs) to define the display
(transfer) function.
Name
Description
sRGB
Select the sRGB standard display
function
Gamma 2.2
Select this display function in case
the display is to replace a CRT dis-
play with a gamma of 2.2
Gamma 1.8
Select this display function in case
the display is to replace a CRT dis-
play with a gamma of 1.8
User
This is a user-programmable display
function (dedicated software needed
to define the associated lookup
table)
Native
If you select Native, a linear LUT will
be selected