background image

7

UNILUX-6  40

Instructions for use

INTRODUCTION

Congratulations on your purchase of this modern Barbas appliance. 

This quality product will provide you with many years of enjoyment due to the fl ame 
effect and warmth that it provides.
This appliance is exempted or recommended for exemption under section 21 of the 
Clean Air Act 1993 and can be used in accordance with the intended use as described 
in this manual in smoke control areas in the UK. The appliance, when sold into the UK 
market, include a factory-installed modifi ed air slider to ensure compliance with smoke 
emission requirements within smoke control areas.

Study this manual carefully before using the fi replace. We recommend you keep this 
manual in a safe place for reference purposes.
The images in this manual are made of a different variant of this appliance. 
The depicted appliance may differ from your device, but the actions and instructions 
shown are fully valid for the unit described here.

“The Clean Air Act 1993 and Smoke Control Areas”

Under the Clean Air Act local authorities may declare the whole or part of the district of 
the authority to be a smoke control area. 
It is an offence to emit smoke from a chimney of a building, from a furnace or from any 
fi xed boiler, if located in a designated smoke control area. 
It is also an offence to acquire an “unauthorised fuel” for use within a smoke control 
area unless it is used in an “exempt” appliance (“exempted” from the controls which 
generally apply in the smoke control area).
The Secretary of State for Environment, Food and Rural Affairs has powers under the 
Act to authorise smokeless fuels or exempt appliances for use in smoke control areas 
in England. 
In Scotland and Wales this power rests with Ministers in the devolved administrations 
for those countries. Separate legislation, the Clean Air (Northern Ireland) Order 1981, 
applies in Northern Ireland. 
Therefore it is a requirement that fuels burnt or obtained for use in smoke control areas 
have been “authorised” in Regulations and that appliances used to burn solid fuel in 
those areas (other than “authorised” fuels) have been exempted by an Order made and 
signed by the Secretary of State or Minister in the devolved administrations.
Further information on the requirements of the Clean Air Act can be found here: 
https://www.gov.uk/smoke-control-area-rules.
Your local authority is responsible for implementing the Clean Air Act 1993 including 
designation and supervision of smoke control areas and you can contact them for 
details of Clean Air Act requirements.

Содержание UNILUX-6 40

Страница 1: ...pliance Serial number Production date Barbas wishes you many cosy evenings with your new appliance This document is an essential part of your appliance Read it carefully before use of the appliance an...

Страница 2: ......

Страница 3: ...y Danny Baijens CEO Name and function Bladel September 18 2018 place and date of issue Signature The performance of the product identified in point 1 is in conformity with the declared performance in...

Страница 4: ...4 UNILUX 6 40 Instructions for use...

Страница 5: ...ions for use CONTENTS Page 1 INTRODUCTION 7 2 SAFETY 8 3 OPERATION 10 4 USING THE APPLIANCE FOR THE FIRST TIME 11 5 USE 14 6 FUEL 21 7 MAINTENANCE 23 8 FREQUENTLY ASKED QUESTIONS 25 9 TECHNICAL DATA 2...

Страница 6: ...6 UNILUX 6 40 Instructions for use...

Страница 7: ...smoke from a chimney of a building from a furnace or from any xed boiler if located in a designated smoke control area It is also an offence to acquire an unauthorised fuel for use within a smoke cont...

Страница 8: ...rous It is not allowed to connect the appliance to a ue which is already connected to another appliance Make sure you know what state your chimney is in Cracks in the chimney may not only lead to damp...

Страница 9: ...appliance to burn rubbish Do not use your appliance as a barbecue This can cause ammable fat deposits to be left in the chimney and hastens the chimney becoming clogged Ensure at all times that child...

Страница 10: ...mney breast ventilation air chimney breast 4 Grate 5 Ashtray 6 Inlet opening 2x grate chimney breast ventilation air chimney breast 7 Combustion air supply slider Combined operation for the primary se...

Страница 11: ...ated with a lacquer layer resistant to high temperature During the rst hours of operation the burning in of the lacquer may result in an unplea sant smell This is harmless however To speed up the proc...

Страница 12: ...eck all available functions before using the appliance for the rst time Check the opening and closing operation of the door Turn the handle all the way down Door is locked Handle forwards The door rel...

Страница 13: ...s Check the operation of the slider for the regulation of the combustion air intake middle below the window Check whether the ashtray is completely empty Report any defects immediately to your dealer...

Страница 14: ...e the chimney is still cold and there is little draught Before the re is lit turn the operating handle completely to the right maximum air supply Open any chimney valve and the valve in the external c...

Страница 15: ...e appliance can be reloaded with coal or smokeless fuel briquettes after approx 1 hour 5 3 INSTRUCTIONS WHILE STOKING 5 3 1 Burning wood logs Using the air supply slider you can adjust the air supply...

Страница 16: ...smokeless fuels After approx 1 hour after starting the re stir the rebed with a suitable poke and reload with approx 1 kg of coal or smokeless fuel briquettes Keep the air slider in the far right pos...

Страница 17: ...arts Any replacement parts must be new original parts Use of non original reconditioned parts will invalidate your warranty Modi cation Do not make modi cations to your appliance Any alteration to you...

Страница 18: ...cent ow of of the ue gasses one can increase the chimney draught To do this remove the upper baf e from the appliance and detach the back part of the baf e by moving this part back and forth until it...

Страница 19: ...nce spits out this is a particular problem with softwood from conifers If your oor contains ammable material an extra oor plate is required The appliance must not be operated with the air control or d...

Страница 20: ...ractor When the door is open the chimney draws in much more air than is necessary for combustion This relatively cool air cools down the appliance Excessive chimney draught The combustion air does not...

Страница 21: ...coal or bri quetted smokeless fuels Unsuitable fuels are Painted bonded chipboard MDF etc or impregnated wood plastic and other ammable waste Stoking an appliance with this is completely forbidden Th...

Страница 22: ...overloaded and can cause excess smoke Each appliance is constructed for a certain maximum amount of fuel Remember that the more fuel you put into your appliance the hotter it will become and overheat...

Страница 23: ...he appliance again Broken ceramic heat resistant glass may not be thrown away in a glass container but must be included in normal household waste Cleaning the appliance Wait for the appliance to cool...

Страница 24: ...ermitted House Ensure that as little dust and as few particles of cigarette smoke candles and oil lamps as possible pollute the air in the room in which the appliance is used Heating of these particle...

Страница 25: ...is the ratio of net capacity and gross capacity How can I keep the glass clean By making a point of using dry clean wood in the appliance Wood that is too damp immediately gives off lots of ash Make s...

Страница 26: ...he result will be a lot of smoke In both cases the combustion temperature is too low This leaves numerous dangerous compounds intact which means more deposits in your chimney and more waste into the e...

Страница 27: ...an depends on the capacity of the extractor system Always consult your installation engineer about this If the combustion air comes directly from outside via a direct connection If there is constant e...

Страница 28: ...sition temperature but condense at lower temperatures are often released These are the tar like components this by product is also known as creosote which is deposited in the chimney and cold parts of...

Страница 29: ...r bottom Steel heat resistant and rust proof Inner lining Steel heat resistant and rust proof Bottom baf e plate Heat resistant panel 2000 kg m3 1300 C Top baf e plate Stainless steel Outside Construc...

Страница 30: ...ims based on the applicable legal provisions Article 2 Warranty conditions 2 1 Should you wish to claim under the warranty please contact your Barbas dealer 2 2 Complaints should be reported as quickl...

Страница 31: ...ts such as glass glass cord thermocouple and the interior of the combustion chamber a similar guarantee is given until after the rst burning Article 6 Liability 6 1 A claim granted by Barbas Bell res...

Страница 32: ...04 070519 340650 Your Barbas dealer...

Отзывы: