background image

6

 ТАБЛИЦА ФОРСУНОК

 NOZZLE TABLE

Технические данные

Technical data

Напряжение

Voltage

V

220-240

Частота

Frequency

Hz

50/60

Мощность горелок

Burner power

 

вспомог.

 

auxiliary

kW

1

 

полубыстр.

 

semi- rapid

kW

1,75

 

быстр.

 

rapid

kW

3

 

быстр.

 

rapid

kW

2,5

 

тройная корона

 

triple ring

kW

3,5

Тип кабеля

Cable type

H05V2V2-F

3x1 mm

2

Длина кабеля

Cable length

cm

90

Горелка

Burner

Тип газа

Gas type

Рабочее 

давление

Applied 

pressure

Расход

Capacity

ø Форсун-

ки

1/100 мм

ø Nozzles

1/100 mm

Номиналь-

ный  расход

Nominal 
capacity

Уменьшен-

ный расход

Reduced 
capacity

Вспомог.

Auxiliary

G30
G31
G30
G31
G20

G25.3

30 mbar
37 mbar
50 mbar
50 mbar
20 mbar
25 mbar

g/h 73
g/h 73
g/h 73
g/h 73

l/h 95

l/h 108

50
50
43
43
71
72

kW 1
kW 1
kW 1
kW 1
kW 1
kW 1

kW 0.45
kW 0.45
kW 0.50
kW 0.50
kW 0.45
kW 0.45

Полубыстр.

Semi- rapid

G30
G31
G30
G31
G20

G25.3

30 mbar
37 mbar
50 mbar
50 mbar
20 mbar
25 mbar

g/h 127
g/h 127
g/h 127
g/h 127

l/h 167
l/h 190

65
65
58
58
96
94

kW 1.75
kW 1.75
kW 1.75
kW 1.75
kW 1.75
kW 1.75

kW 0.45
kW 0.45
kW 0.50
kW 0.50
kW 0.45
kW 0.45

Быстр.

Rapid 3 kW

G30
G31
G30
G31
G20

G25.3

30 mbar
37 mbar
50 mbar
50 mbar
20 mbar
25 mbar

g/h 218
g/h 218
g/h 218
g/h 218

l/h 286
l/h 325

85
85
75
75

128
126

kW 3
kW 3
kW 3
kW 3
kW 3
kW 3

kW 0.85
kW 0.85
kW 0.95
kW 0.95
kW 0.85
kW 0.85

Быстр.

Rapid 2,5 kW

1PLB0604#-00--1 

PLB0604#-00--1

1PLB0904T#-00--1 

 PLB0904T#-00--1

G30
G31
G30
G31
G20

G25.3

30 mbar
37 mbar
50 mbar
50 mbar
20 mbar
25 mbar

g/h 182
g/h 182
g/h 182
g/h 182

l/h 238
l/h 238

79
79
68
68

106
110

kW 2,5
kW 2,5
kW 2,5
kW 2,5
kW 2,5
kW 2,5

kW 0.85
kW 0.85
kW 0.95
kW 0.95
kW 0.85
kW 0.85

двойная корона

Double ring

G30
G31
G30
G31
G20

G25.3

30 mbar
37 mbar
50 mbar
50 mbar
20 mbar
25 mbar

g/h 255
g/h 255
g/h 255
g/h 255

l/h 334
l/h 380

94
94
75
75

140
135

kW 3.5
kW 3.5
kW 3.5
kW 3.5
kW 3.5
kW 3.5

kW 1.40
kW 1.40
kW 1.65
kW 1.65
kW 1.40
kW 1.40

Содержание 1PLB0604#-00--1 series

Страница 1: ...bs QVWDOODWLRQ DQG XVH PDQXDO 1PLB0604 00 1 PLB0604 00 1 1PLB0904T 00 1 PLB0904T 00 1 1PLB0902T 00 1 PLB0902T 00 1 1PLB1203T 00 1 PLB1203T 00 1 1PLBC0902T 00 2 PLBC0902T 00 2 PLB0604F 00 PLB0904TF 00...

Страница 2: ...ral information 2014 35 UE 2014 30 UE 2016 426 Themanufacturerreservestherighttomakeanychanges deemed suitable to the product without prior notice The drawings installation diagrams and tables contain...

Страница 3: ...power mains 10 Gas connection 12 Regulating the minimum 14 Gas conversione 15 Built in unit installation 16 USAGE 19 Safety warnings 19 Before starting 21 Understanding the appliance 21 Control panel...

Страница 4: ...455 510 895 870 382 68 190 270 68 12 382 68 188 270 68 12 mm 65 65 1PLB0604 00 1 587 80 R 6 R 6 510 615 R 6 mm mm 90 90 120 120 1PLB1203T 00 1 1PLBC0902T 00 2 68 383 68 442 268 12 1150 455 R 6 510 870...

Страница 5: ...5 mm mm mm mm 65 65 90 90 120 120 90 90 5 1 0 80 40 80 7 6 5 1 0 1 6 480 400 80 400 80 7 6 5 480 80 80 80 40 80 80 40 80 80 40 80 PLB0604F 00 PLB1203TF 00 PLB1203TF 00 PLB1203TF 00...

Страница 6: ...94 kW 1 75 kW 1 75 kW 1 75 kW 1 75 kW 1 75 kW 1 75 kW 0 45 kW 0 45 kW 0 50 kW 0 50 kW 0 45 kW 0 45 Rapid 3 kW G30 G31 G30 G31 G20 G25 3 30 mbar 37 mbar 50 mbar 50 mbar 20 mbar 25 mbar g h 218 g h 218...

Страница 7: ...nel only as specified in this booklet The connection systems gas and electric and installa tionroomsmustbesuitableandsatisfythesafetystand ards in force in the country of use protective isolating swit...

Страница 8: ...s polystyrene etc unattended astheyarea potential hazard for children and animals danger of suffocation Move the appliance to the installation location using appropriate personal safety equipment figu...

Страница 9: ...mbustion as specified in the standards in force UNI CIG 7129 and 7131 Openings with an area of at least 100 cm2 must be constructed in such a way so that they cannot be obstructed from neither the ins...

Страница 10: ...ion of the two appliances must be independent for electrical safety reasons The power cord must NOT be crushed or rolled up come into contact with any type of liquid sharp or hot objects or corrosive...

Страница 11: ...f the appliance is already connected disconnect the electrical power and shut off gas supply taps To access the electrical connections remove the cover from the terminal board by unscrewing the screws...

Страница 12: ...ntenance operations Checkthegastypewhichwillpowertheappliance Liquid Gas G30 G31 or Methane G20 25 and ensure that the appliance is compatible with this in the case where it is not compatible adapt it...

Страница 13: ...regulating the minimum if necessary consult page 14 When satisfied with the hotplate please instruct the user on the correct method of operation In case the appliance fails to operate correctly after...

Страница 14: ...towards the left to increase the flame in order to ascertain the desired idle setting If powered by Universal LPG the adjustment screw controlling the idle mode setting must be completely screwed in...

Страница 15: ...the identification mark and the nozzle table on page 6 In thecasewhereyoucarryoutanapplianceregulationopera tion for a gas type that differs from the above mentioned appendedtothepresentdocumentation...

Страница 16: ...et in which you will be installing the appliance is in perfect condition and completely stable Standard DIN 68930 Prepare an embedded hole with measurements as specified in figures9A 9B iftheappliance...

Страница 17: ...17 17 mm mm 90 90 90 90 875 435 458 898 875 435 R 7 5 mm mm 860 490 513 873 860 490 R 7 5 mm mm 120 120 1130 435 458 1153 1130 435 R 7 5 Built in Flush 1 2 1 1 mm mm 9B...

Страница 18: ...10A part 2 Seal the gap between the panel and lowering with sili cone figure 10A part 3 and remove any excess figure 10A part 4 EMBEDDED SURFACES Subsequently arrangetheapplianceabovetheembed ded hole...

Страница 19: ...vice Centre and re port the data indicated on the data plate Thisapplianceisnotsuitedforusebypersons including children with physical sensorial or mental difficulties or lacking proper experience and...

Страница 20: ...verheatuptincansorhermeticallyclosedcontainersontheap pliance theexcesspressuregeneratedbytheheatmaycausecon tainerstoexplode consequentlyleadingtoseriouspersonalinjury Monitor the appliance during th...

Страница 21: ...zato solamente in locale ben areato Consultare il libretto istruzioni prima di installare e usare l aparecchio REGOLATO A GAS G20 N XXXXXXXXX CATEGORIA II 2H3 IT F lli BARAZZA s r l MADE IN ITALY Qn g...

Страница 22: ...der to determine which knob controls which cook ingzone consultthevelvettouchscreenwhichappears nexttotheknobs whichclearlyanddefinitivelyidentifies which knob regulates which burner figures 13A 13B 6...

Страница 23: ...g its com ponents as specified in the Chapter Routine Maintenance on page 28 During this time the appliance may emit smoke or un pleasant odours due to the burning of the grease used in the factory pr...

Страница 24: ...king the gas flow from the nozzle subse quently preventing unburned gas from filling the room Switching on the burners 1 figure 14 Press down fully on the knob regulating the burner you wish to switch...

Страница 25: ...ialsandsuitableforcontactwithfoods For enhanced burner performance you must use containers withdiametersproportionedtotheburnertypechosen so that you get maximum performance using the minimum amount o...

Страница 26: ...ew minutes after use some parts of the appliance reach extremely high temperatures Do not touch these parts without suitable personal protection Switching off the burners 5 Once you have finished cook...

Страница 27: ...rts of the appliance using only the procedures and products indicated in this manual in particular do not use abrasive sponges scrapers acidic or aggressive detergents steam or pressure cleaning devic...

Страница 28: ...t been accidentally moved from the off position Flame distributors burners racks after the com ponents have cooled down remove them from their housing and wash them with hot water mixed with washing u...

Страница 29: ...pter disconnect it from the power and gas supply Ensurethatuponfinishingcleaning thatyouhave correctly replaced the racks taking care not to invert them Theracksmustbestableandmustrestonthehob without...

Страница 30: ...than Italy you must comply with the regulations in force in your country Before disposing of the appliance render it unusable by removing the power cord AFTER SALES SERVICE Barazza srl ensures you th...

Страница 31: ......

Страница 32: ...o grafico Artlinea cod PLAB7 rev05 05 2018 Barazza srl 31025 Sarano di S Lucia di Piave TV ITALIA Via Risorgimento 14 Tel 39 0438 62888 Fax 39 0438 64901 info barazzasrl it www barazzasrl it taste of...

Отзывы: