Operation manual
Bär SmartControl 2.0
40000001186_EN_03.docx
Page 12 / 39
Date: 31/03/2020
3.5 Display indicators
Designation
Display
Description
LED flickers
The LED does not illuminate constantly with lower
luminosity.
LED flashes
The LED blinks briefly and then remains dark for
longer.
A sequence lasts about 1 second
LED blinks
The LED blinks at regular intervals for approx. 0.5
seconds.
LED on
The LED illuminates constantly.
Process successful
The process (e.g. pairing) was successfully
completed.
The middle 3 LEDs illuminate for approx. 0.7
seconds.
Process not successful
The process (e.g. pairing) failed and was cancelled.
The middle LEDs blink twice briefly.
3.5.1
Truck/trailer prioritisation display
The LED under the truck symbol and the LED under the trailer symbol indicate several states. There is
therefore a clear prioritisation. Higher prioritised states superimpose states with a lower prioritisation with
their signalling.
1. LED blinks
Cargolift is not in driving position
Highest priority
2. LED flashes
The “RadioKey” function is active
3
LED
illuminates
Control voltage is switched on
4
LED flickers
The pairing of the system was disconnected
Lowest priority
3.5.2
Radio range
Designation
Display
Description
Hand-held transmitter in near
field
Green LED illuminates:
Hand-held transmitter is located in the near field of the
logged in system.
Hand-held transmitter in
working field
Green LED blinks:
Hand-held transmitter is located in the working field of
the logged in system.
Hand-held transmitter in radio
range
Green LED flickers:
Hand-held transmitter is located in the radio range of
the logged in system.
Hand-held transmitter logged
in to the truck
The red LED under the truck symbol illuminates:
Hand-
held transmitter is logged in to the truck’s
system.
This control voltage of the Cargolift is on.
Hand-held transmitter logged
in to the trailer
The red LED under the trailer symbol illuminates:
The hand-
held transmitter is logged in to the trailer’s
system.
This control voltage of the Cargolift is on.