background image

Building Automation Products, Inc., 

750 North Royal Avenue, Gays Mills, WI  54631 USA

Tel: +1-608-735-4800 • Fax: +1-608-735-4804 

E-mail: [email protected] • Web: www.bapihvac.com

Google Play and the Google Play logo are trademarks of Google LLC.

Apple and the Apple logo are trademarks of Apple Inc., registered in the U.S. and other countries and regions. App Store is a service mark of Apple Inc.

Содержание Blu-Test

Страница 1: ...ows hands free measuring in ducts Reversible belt clip OLED displays measurements and cycles through other displays battery level log indicator etc Sealed probe tip can be used in liquids Gauge Graph...

Страница 2: ...10 11 Storage 10 12 Diagnostics 10 13 Recalibration Information 10 14 Specifications 11 Bl Test is a suite of handheld test instruments that communicate via Bluetooth 4 2 to the user s enabled Android...

Страница 3: ...ctivity no logging no active App present On Probe Log Storage Probe can store up to a million readings in a maximum of 31 log files Once the memory is full a new log file will automatically overwrite...

Страница 4: ...r download from the probe to the Bl Test application Tap the top left Download button to download the checked files to your device or tap the white down arrow to download individual files The down arr...

Страница 5: ...umidity log is selected as the primary log so the scale values on the axes only apply to that graph Sect 6 Application Logs Screen Overview Bl Test Application The Application Logs Screen different fr...

Страница 6: ...sites and locations screens along with exporting a comma separated values csv file of your sites and locations Fig 15 Sites Screen before adding sites Fig 16 Sites Screen with site added Fig 17 Locati...

Страница 7: ...ool will then provide the transmitter specifications including the accuracy at 8 and 16 mA accuracy at 25 50 and 75 of span linearity and power output shift The Tools Section of the Home Screen includ...

Страница 8: ...he application discovers Changes to specific probes can still be made via the gauges view of the specific probe Resistance to Temperature This tool will calculate the temperature when you enter the re...

Страница 9: ...Leave the probe in place for 2 minutes or until the reading stabilizes Outside air sensor measurement requires that the Bl Test probe be placed next to the outside air sensor This may require a ladde...

Страница 10: ...1 The log file may be very large so give it time to download A week long log file can take up to 30 minutes to download from the probe to the application This is normal behavior Possible Problem iOS...

Страница 11: ...sure Probes Low Range 0 25 of FS Span 1 to 1 WC 250 to 250 Pa at 77 F 25 C Standard Range 0 25 of FS Span 5 to 5 WC 1 250 to 1 250 Pa at 77 F 25 C Burst Pressure Differential Pressure Probes Low Range...

Страница 12: ...735 4800 Fax 1 608 735 4804 E mail sales bapihvac com Web www bapihvac com Google Play and the Google Play logo are trademarks of Google LLC Apple and the Apple logo are trademarks of Apple Inc regis...

Отзывы: